2022
DOI: 10.1161/jaha.121.024175
|View full text |Cite
|
Sign up to set email alerts
|

Gravitational Dose‐Response Curves for Acute Cardiovascular Hemodynamics and Autonomic Responses in a Tilt Paradigm

Abstract: Background The cardiovascular system is strongly dependent on the gravitational environment. Gravitational changes cause mechanical fluid shifts and, in turn, autonomic effectors influence systemic circulation and cardiac control. We implemented a tilt paradigm to (1) investigate the acute hemodynamic response across a range of directions of the gravitational vector, and (2) to generate specific dose‐response relationships of this gravitational dependency. Methods … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 117 publications
(136 reference statements)
1
6
0
Order By: Relevance
“…During the HUTT, the orthostatic changes in the hemodynamic parameters were identical to those presented in the literature [ 43 , 44 , 45 ]. A graded increase or decrease in tilt angle was accompanied by a proportional change in hemodynamic indices (except SBP) and the autonomic nervous system [ 46 ].…”
Section: Discussionmentioning
confidence: 99%
“…During the HUTT, the orthostatic changes in the hemodynamic parameters were identical to those presented in the literature [ 43 , 44 , 45 ]. A graded increase or decrease in tilt angle was accompanied by a proportional change in hemodynamic indices (except SBP) and the autonomic nervous system [ 46 ].…”
Section: Discussionmentioning
confidence: 99%
“…Among them, the gravitational factor is a key factor in cardiac preload and myocardial contractility. Changes in body position can cause cardiovascular reflexes, causing orthostatic venous return obstruction, which leads to reduced cardiac output ( Bergenwald et al, 1977 ; Matzen et al, 1991 ; Harms et al, 2003 ; Dorogovtsev et al, 2021 ; Whittle et al, 2022 ). During supine head-up tilt (HUT), a reduction in SV is associated with a drop in pleural fluid content, cardiac volume, central blood pressure, and hemodynamic changes ( Van Lieshout et al, 2005 ; Cheung et al, 2020 ; Dorogovtsev et al, 2021 ).…”
Section: Discussionmentioning
confidence: 99%
“…Additional information regarding the employed instrumentation, usage of devices, and environmental calibration procedure can be found in refs. 12 , 30 .…”
Section: Methodsmentioning
confidence: 99%