2005
DOI: 10.1007/s00264-005-0671-5
|View full text |Cite
|
Sign up to set email alerts
|

Greater accuracy in positioning of the acetabular cup by using an image-free navigation system

Abstract: In a prospective and randomised clinical study, acetabular cups were implanted free-hand (control group n=22) or with computer assistance using an image-free navigation system (study group n=23). The cup position was determined postoperatively on pelvic CT. An average inclination of 42.3°(range: 30°-53°; SD±7.0°) and an average anteversion of 24.0°(range: −3°to 51°; SD±15.0°) were found in the control group, and an average inclination of 45.0°(ranage: 40°-50°; SD±2.8°) and an average anteversion of 14.4°(range… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
79
2
9

Year Published

2005
2005
2021
2021

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 107 publications
(93 citation statements)
references
References 21 publications
3
79
2
9
Order By: Relevance
“…A ''safe'' zone of acetabular component position was suggested for small-bearing metal-on-polyethylene THA in a retrospective study [20]. Although this study had some weaknesses, the safe range of 30°to 50°suggested in that study has been generally accepted as a gold standard by surgeons [14,16,25], which was also targeted in our study. An AP pelvis radiograph remains a universal tool for assessing acetabular inclination angles after hip arthroplasties in the United States.…”
Section: Discussionmentioning
confidence: 95%
See 2 more Smart Citations
“…A ''safe'' zone of acetabular component position was suggested for small-bearing metal-on-polyethylene THA in a retrospective study [20]. Although this study had some weaknesses, the safe range of 30°to 50°suggested in that study has been generally accepted as a gold standard by surgeons [14,16,25], which was also targeted in our study. An AP pelvis radiograph remains a universal tool for assessing acetabular inclination angles after hip arthroplasties in the United States.…”
Section: Discussionmentioning
confidence: 95%
“…Numerous studies have documented surgical navigation holds the promise for providing most accurate intraoperative guidance for acetabular component position [10,16,29,34]. However, the equipment is not available to most surgeons.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Within the level of variability considered here, CAS alignment produced resultant ROM that was always within acceptable limits. While CAS techniques decrease variability in implant alignment [13][14][15]24], this study provides quantitative support for the ability of CAS methods to decrease the probability of hip dislocation compared to conventional techniques.…”
Section: Discussionmentioning
confidence: 95%
“…There is also natural variability in how precisely a surgical plan can be executed [20]. Computer-assisted surgical (CAS) techniques reduce but do not eliminate this variability [13][14][15]. However, the effect of reduced variability on a clinical outcome such as ROM has not been fully determined.…”
Section: Introductionmentioning