2018 7th International Conference on Renewable Energy Research and Applications (ICRERA) 2018
DOI: 10.1109/icrera.2018.8566730
|View full text |Cite
|
Sign up to set email alerts
|

Grid Connection of a Converter Controlled Squirrel-Cage Induction Generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…A feeder simulator was developed in [14] in order to assess the IG influence on the PCC in case of grid connection, loading and disconnection. To decrease the inrush current specific to the grid connection process, a system consisting of a power electronic converter plus a controllable load was investigated in [15], while in Reference [16] a thyristor-based Soft-starter was employed. A three-phase IG can also be connected to a single-phase grid through an uncontrolled bridge rectifier plus a single-phase inverter [17].…”
Section: Introductionmentioning
confidence: 99%
“…A feeder simulator was developed in [14] in order to assess the IG influence on the PCC in case of grid connection, loading and disconnection. To decrease the inrush current specific to the grid connection process, a system consisting of a power electronic converter plus a controllable load was investigated in [15], while in Reference [16] a thyristor-based Soft-starter was employed. A three-phase IG can also be connected to a single-phase grid through an uncontrolled bridge rectifier plus a single-phase inverter [17].…”
Section: Introductionmentioning
confidence: 99%
“…Then, the converter is connected to the stator terminals and starts the building-up process of generator voltage. At this stage, the generator voltage amplitude equals the grid voltage amplitude, but the generator frequency differs from the grid frequency and depends on generator speed and rotor slip [16]. The grid and generator voltage vectors overlap periodically and the period equals…”
Section: The Proposed Methods Of Grid Connection Of the Inductionmentioning
confidence: 99%
“…The parallel-connected electronic converter, which usually satisfies the reactive power demand of an induction generator, may decrease an inrush current of the generator during grid connection transient [3]- [16]. When the power converter is permanently connected to the grid and the induction generator is connected separately as an unexcited machine, an inrush current is reduced to only about a few percent [3].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In [33], there is a process of decreasing the inrush current during the connection of the squirrel cage induction generator to the distribution grid. An investigation of skew effect is presented by [34], whose work focuses on the steady-state and transient dynamics behavior of the squirrel cage induction generator in the power grid.…”
Section: Introductionmentioning
confidence: 99%