2019 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America) 2019
DOI: 10.1109/isgt-la.2019.8895424
|View full text |Cite
|
Sign up to set email alerts
|

Grid Support of Small-scale PV Generators with Reactive Power Injection in Distribution Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…The parameters obtained above are used to calculate the current İn in every line of the system, as shown in (11). In the first iteration, the node voltages are equal to the reference voltage and, after that, the node voltage updated is obtained in (12), considering the transformation ratio α n and impedance Z t n of transformers and voltage regulators.…”
Section: Methods For Power Flowmentioning
confidence: 99%
See 2 more Smart Citations
“…The parameters obtained above are used to calculate the current İn in every line of the system, as shown in (11). In the first iteration, the node voltages are equal to the reference voltage and, after that, the node voltage updated is obtained in (12), considering the transformation ratio α n and impedance Z t n of transformers and voltage regulators.…”
Section: Methods For Power Flowmentioning
confidence: 99%
“…The impedance matrix method uses the line Equations ( 10) and (11), thus considering a system with n nodes and x being the fault point; the calculation starts with the determination of the Z eq abc impedance matrix, from source to shorting point, obtained by calculating the Thevenin equivalent impedance, Z Th x , with the sum of the line impedances Z l abcn , as shown in (15). The post-fault source voltage, Vsabc , will be obtained from (16), where İf abc is the fault current, Z f abc is the fault impedance, Vf abcx is the fault point voltage, Vf gx is the reference line to ground fault voltage, and VGD abc is the voltage of one of the generators of the n-node system.…”
Section: Methods For Short Circuitmentioning
confidence: 99%
See 1 more Smart Citation
“…Solar plants inject generally reactive power components for voltage support. In [73], reactive power is injected to support line-to-ground and three line-to-ground faults. In [74], the effect of injecting negative sequence reactive current into the grid in case of asymmetrical faults is investigated.…”
Section: Voltage Supportmentioning
confidence: 99%
“…But, considering the growth of PV systems and other renewable energies connected to power grid, current grid codes are adapting new impositions to mandate that distributed energy resources have specific grid support functions. This is why power inverters must be incorporate control solutions to operate while managing anti-islanded protections, voltage/frequency ride-through, and active/reactive power control during perturbations [73]. In order to satisfy grid codes regulations, control package must be include controls of voltage, frequency, active power, reactive power reference and power factor [79,98].…”
Section: Identified Findingsmentioning
confidence: 99%