2008
DOI: 10.1016/j.jvs.2008.02.046
|View full text |Cite
|
Sign up to set email alerts
|

Guidelines for Clinical Studies with Compression Devices in Patients with Venous Disorders of the Lower Limb

Abstract: Objectives: Endovascular repair of descending thoracic aortic lesions is associated with a substantial risk of perioperative spinal cord ischaemia (SCI) which may lead to permanent paraplegia.We performed a retrospective analysis of our experience in the endovascular treatment of descending thoracic aortic lesions to define the incidence of SCI and to identify factors that contributed to its development.Methods: 67 consecutive patients underwent stent graft repair for descending thoracic aortic lesions includi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2009
2009
2017
2017

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(22 citation statements)
references
References 0 publications
0
22
0
Order By: Relevance
“…Calculations based on the mean of the repetitions split by position and state gave CIs that were at most 5 mmHg from 50 mmHg. According to the guidelines for categorising the sub‐bandage pressure as strong , we achieved this in all the cases both for the separate repetitions and for the mean values.…”
Section: Resultsmentioning
confidence: 88%
See 4 more Smart Citations
“…Calculations based on the mean of the repetitions split by position and state gave CIs that were at most 5 mmHg from 50 mmHg. According to the guidelines for categorising the sub‐bandage pressure as strong , we achieved this in all the cases both for the separate repetitions and for the mean values.…”
Section: Resultsmentioning
confidence: 88%
“…Two pressure sensors were placed on the leg of a healthy female volunteer at the recommended places for sub‐bandage pressure monitoring —at the positions called B1 and C. The B1 position is approximately 10–15 cm proximal to the medial malleolus where the Achilles tendon changes into the calf muscles, while the C position is where the calf is at its maximum girth. The pressure measurement device that was used was PicoPress by Microlab Italia, a sensor that is thin and flexible . A previous study and our own tests showed that PicoPress ® was the most reliable device currently on the market.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations