2017
DOI: 10.2343/geochemj.2.0470
|View full text |Cite
|
Sign up to set email alerts
|

H<sub>2</sub>O, CO<sub>2</sub>, F, S, Cl, and P<sub>2</sub>O<sub>5</sub> analyses of silicate glasses using SIMS: Report of volatile standard glasses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
18
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 41 publications
(18 citation statements)
references
References 47 publications
0
18
0
Order By: Relevance
“…The indium discs were coated with gold and the Cl concentrations were determined using SIMS (CAMECA; IMS 1280HR) at the Kochi Institute for Core Sample Research, the Japan Agency for Marine-Earth Science and Technology (JAMSTEC) 52,53 . A 20 kV (10 kV at the ion source and −10 kV at the sample surface) primary Cs + ion beam of 300–700 pA was defocused to a 15 μm diameter spot on the sample surface.…”
Section: Methodsmentioning
confidence: 99%
“…The indium discs were coated with gold and the Cl concentrations were determined using SIMS (CAMECA; IMS 1280HR) at the Kochi Institute for Core Sample Research, the Japan Agency for Marine-Earth Science and Technology (JAMSTEC) 52,53 . A 20 kV (10 kV at the ion source and −10 kV at the sample surface) primary Cs + ion beam of 300–700 pA was defocused to a 15 μm diameter spot on the sample surface.…”
Section: Methodsmentioning
confidence: 99%
“…To analyze the hydrogen and carbon abundances in the samples, H/ 18 O and 12 C/ 18 O were monitored simultaneously using electron multipliers. The calibration lines for hydrogen and carbon were obtained from silicate glass standards (Shimizu et al, ). A primary ion beam of 133 Cs + with an accelerating voltage of 14.5 keV and a beam current of 1.8–2.5 nA were applied.…”
Section: Methodsmentioning
confidence: 99%
“…Figure 2 shows the Raman and IR spectra in the [OH − ] vibrational region, collected from two crystals from runs R623 and R624 in this study. Water content was measured using the SIMS technique, with Cameca IMS-1280 ion microprobe installed at School of Ocean and Earth Science and Technology, University of Hawaii at Manoa (Honolulu, HI, USA), with the calibration curves constructed using standards employed in previous studies [34,35]. Chemical composition analyses were carried out by the electron microprobe in energy dispersive mode with FEI Quanta 250 electron microscopy installed at the Department of Earth Sciences, National Cheng Kung University.…”
Section: Methodsmentioning
confidence: 99%