2014
DOI: 10.1016/j.cmpb.2013.12.018
|View full text |Cite
|
Sign up to set email alerts
|

Hand gesture guided robot-assisted surgery based on a direct augmented reality interface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
39
0
3

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 101 publications
(42 citation statements)
references
References 13 publications
0
39
0
3
Order By: Relevance
“…Our system can also be extended to include the control and manipulation of a robot for RF needle insertion. In [22], we described a natural gestures control method for robust interaction with the AR and the surgical robot system. The front camera of the table computer can be used for recognition of hand gestures of surgeons so that strictly sterile interaction can be realized.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Our system can also be extended to include the control and manipulation of a robot for RF needle insertion. In [22], we described a natural gestures control method for robust interaction with the AR and the surgical robot system. The front camera of the table computer can be used for recognition of hand gestures of surgeons so that strictly sterile interaction can be realized.…”
Section: Discussionmentioning
confidence: 99%
“…The built-in forward camera of the tablet can also provide an alternative for touchless gesture recognition as in [22] for AR operation if sterility is strictly required.…”
Section: Interactive Surgical Guidancementioning
confidence: 99%
“…The actions to test the collaborative robot take into account the various robotic actions covered by the literature [20], among which are the guidance of the laparoscopic camera for the safe movement of the endoscope [21] or a needle insertion [22], the prediction of the end point [23,24], the knotting and unknotting on suture procedures [25], or grasping and lifting on tissue retraction [26]. Ultimately, we selected three actions to be performed by the collaborative robot: center the image from the endoscope, indicate a place to suture, and stretch the thread to suture.…”
Section: Algorithm For Movement Detectionmentioning
confidence: 99%
“…Los primeros usos de este dispositivo para tareas ajenas a su concepción inicial de instrumento para video juegos, se dieron en sistemas de reconocimiento de gestos de manera general ( [15], [16], [17], [18]). Posteriormente se empezó a utilizar el dispositivo en diversas aplicaciones, entre ellas la replicación de movimientos en robots ( [19], [20]), la rehabilitación de pacientes [21], [22] y, finalmente, su uso como interfaz natural para el control de dispositivos quirúrgicos, como el caso del uso del Kinect para reconocer un protocolo de gestos en la inserción de guías dentro del paciente [23]; la evaluación del mismo dispositivo como generador de movimientos en un simulador quirúrgico [24], o el uso del Kinect para el reconocimiento de un protocolo de gestos en una biopsia cerebral [25]. El mayor aporte de este proyecto es la utilización del Kinect para mover dos robots quirúrgicos en operaciones de laparoscopia.…”
Section: Dispositivo Kinect Y Su Interacción Con Robosurgeryunclassified