2002
DOI: 10.1258/135763302320272220
|View full text |Cite
|
Sign up to set email alerts
|

Hand-held digital video-camera for eye examination and follow-up

Abstract: We developed a hand-held digital colour video-camera for eye examination in primary care. The device weighed 550 g. It featured a charge-coupled device (CCD) and corrective optics. Both colour video and digital still images could be taken. The video-camera was connected to a PC with software for database storage, image processing and telecommunication. We studied 88 normal subjects (38 male, 50 female), aged 7-62 years. It was not necessary to use mydriatic eye drops for pupillary dilation. Satisfactory digita… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2004
2004
2013
2013

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…The simplified hand‐held digital colour videocamera (MediTell) intended to be used by general practitioners provided excellent digital images of the whole face and the anterior eye, but the diameter of one imaging field of the ocular fundus was only about three disc diameters and imaging was possible to only about 20 ° from the central fundus (Saari et al 2002). The quality of still images of the ocular fundus was worse than that of the continuous fundus videophotography (Saari et al 2002). Still images used in this study were obscure, only occasionally showing haemorrhages and hard exudates, and could not demonstrate MAs, IRMAs or neovascularization.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The simplified hand‐held digital colour videocamera (MediTell) intended to be used by general practitioners provided excellent digital images of the whole face and the anterior eye, but the diameter of one imaging field of the ocular fundus was only about three disc diameters and imaging was possible to only about 20 ° from the central fundus (Saari et al 2002). The quality of still images of the ocular fundus was worse than that of the continuous fundus videophotography (Saari et al 2002). Still images used in this study were obscure, only occasionally showing haemorrhages and hard exudates, and could not demonstrate MAs, IRMAs or neovascularization.…”
Section: Discussionmentioning
confidence: 99%
“…Two single (still) images were taken using a white‐light flash for illumination. Captured JPEG images had a field area of about 20 ° (Saari et al 2002). All images were captured by a professional photographer at the Turku University Eye Clinic.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…1,5,6,[11][12][13] Many small towns have no ophthalmologists, because of the shortage of ophthalmologists. Some trials were conducted in the field of ophthalmology, 5-10 but the conditions to successful tele-medicine are insufficient.…”
mentioning
confidence: 99%