Abstract: This paper presents a power system harmonic elimination using the mixed adaptive linear neural network and variable step-size leaky least mean square (ADALINE-VSSLLMS) control algorithm based active power filter (APF). The weight vector of ADALINE along with the variable step-size parameter and leakage coefficient of the VSSLLMS algorithm are automatically adjusted to eliminate harmonics from the distorted load current. For all iteration, the VSSLLMS algorithm selects a new rate of convergence for searching an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…Case 1 : If the APF monitors harmonic components only (Blasko, 2007; Garanayak and Panda, 2015; Pereira et al, 2011; Ponnusamy and Narri, 2012), then load current becomes…”
Section: Harmonics and Reactive Power Compensationmentioning
confidence: 99%
See 1 more Smart Citation
“…Case 1 : If the APF monitors harmonic components only (Blasko, 2007; Garanayak and Panda, 2015; Pereira et al, 2011; Ponnusamy and Narri, 2012), then load current becomes…”
Section: Harmonics and Reactive Power Compensationmentioning
confidence: 99%
“…However, it is restricted by its high rating inverter used as an APF and large value of DC bus capacitor voltage; that is, the required voltage should be more than 50% of the supply voltage. A shunt hybrid active power filter (SHAPF) topology has been proposed for the sake of improving filtering performance, scale down the rating of an APF and avoiding the resonance problems introduced by the PPFs (Garanayak and Panda, 2015; Lam and Wong, 2014; Rahmani et al, 2013; Srianthumrong and Akagi, 2003). The structure of three-phase SHAPF is shown in Figure 1.…”
Section: Introductionmentioning
confidence: 99%
“…A least mean square (LMS) control based on Variable step‐size leaky least mean square based algorithm has been used to control shunt active power compensator for removing the harmonics from the supply current. The step size for weight adjustment changes automatically . However, the application of improved Adaline as a new PLL as well as for load compensation is not reported in literature.…”
Section: Introductionmentioning
confidence: 99%
“…The currents of the linear motor and the loads of the pump differ according to the working conditions of the oil well [13,14]. The operating current curves of the linear motor in different working conditions are shown in Figure 2.…”
Section: Feature Extractionmentioning