2014
DOI: 10.1016/j.ijepes.2014.02.023
|View full text |Cite
|
Sign up to set email alerts
|

Harmonic elimination of cascaded H-bridge multilevel inverter based active power filter controlled by intelligent techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…Fourier transform technique is utilized for the output voltage of the MLI, which is having symmetry in odd quarter-wave [37], [38]. The MLI Fourier series expression is expressed as (10).…”
Section: Harmonics Reduction Methods and Fourier Transformmentioning
confidence: 99%
See 1 more Smart Citation
“…Fourier transform technique is utilized for the output voltage of the MLI, which is having symmetry in odd quarter-wave [37], [38]. The MLI Fourier series expression is expressed as (10).…”
Section: Harmonics Reduction Methods and Fourier Transformmentioning
confidence: 99%
“…An excellent experience presentation and reasoning skills of fuzzy sense that possess the abilities to change over the starring position of the association to accomplish the desired output [48]. An adaptive network is based on the FIS that combines practically all the types of neural network simulations [37]. ANFIS is a hybrid soft computing model composed of a neuro-fuzzy system in which a fuzzy inference system can be trained by a neural network learning algorithm.…”
Section: B Anfis Controllermentioning
confidence: 99%
“…In recent years, with the large-scale deployment of distributed generation, as an energy conversion interface between distributed energy and power grid or AC load, the DC-AC link of distributed generation has attracted extensive attention [1]- [2]. Due to the low total standing voltage (TSV), low total harmonic 1 distortion (THD) and effective reduction of electromagnetic interference, multilevel inverters have become one of the preferred circuit configurations for high efficiency in the DC-AC link [3]. There are many traditional multilevel inverters such as neutral point clamped (NPC) multilevel inverter [4], flying capacitor (FC) multilevel inverter [5], and cascaded H-bridge (CHB) multilevel inverter [6].…”
Section: Introductionmentioning
confidence: 99%
“…Reducing electricity consumption at the grid, particularly at the distribution level, relieving the transformer from excess loading, can solve the issue (Elphick et al 2015). With a fixed capacitor or reactor compensation, the power factor can go leading or lagging compensation does not give full benefits to the consumer in a desirable manner as the load changes continuously (Rao et al 2014; Fig. 1 Reactive power variations of system under consideration 2018b).…”
Section: Introductionmentioning
confidence: 99%