Harmonic suppression in HVDC system using a modified control method for hybrid active DC filter

Abstract: A shunt hybrid active DC filter (HADF) is applied to eliminate DC transmission line current harmonics in HVDC transmission system. Since the harmonics increase transmission line losses and disturb control and monitoring equipments so HADF are used to suppress harmonics on DC transmission lines. In this paper a modified method is presented to control the shunt HADF which is not dependent on HVDC circuit parameters. HADF by injecting the compensating current to DC transmission line with the modified method suppr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 4 publications
0
10
0
Order By: Relevance
“…(ii) Those interharmonics close to fundamental or harmonics may not be detected properly [33]. Actually, many studies focused on interharmonic sources, impacts, measurement, limit values and mitigation can be found in the recent literature [34][35][36][37][38][39][40][41][42][43][44][45][46]. The research should be carried on in finding accurate interharmonic magnitude and frequency for adjacent harmonics/interharmonics [47].…”
Section: Research Articlementioning
confidence: 99%
“…(ii) Those interharmonics close to fundamental or harmonics may not be detected properly [33]. Actually, many studies focused on interharmonic sources, impacts, measurement, limit values and mitigation can be found in the recent literature [34][35][36][37][38][39][40][41][42][43][44][45][46]. The research should be carried on in finding accurate interharmonic magnitude and frequency for adjacent harmonics/interharmonics [47].…”
Section: Research Articlementioning
confidence: 99%
“…However, its cost and reliability are concerned in high‐voltage applications. To tackle this issue, the hybrid filtering has been proposed, which combines passive filters and active filters 17‐19 . The passive part is mainly used for the reactive power compensation, which greatly reduces the voltage and power rating of the active part, leading to a reduction in the cost.…”
Section: Introductionmentioning
confidence: 99%
“…(iv) Iterative harmonic analysis is unable to model non-linear load. For the above reasons, the research work in interharmonics measurement is still on the way [25][26][27][28][29][30][31][32][33][34][35][36][37][38].…”