Harmonics Mitigation in Industrial Sector by using Space Vector PWM and Shunt Active Power Filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 16 publications
0
1
0
Order By: Relevance
“…The ratio of the sum of the RMS values of all harmonic components up to a certain order to the RMS values of the fundamental components. A measurement of a THD present in a signal is defined as the ratio of the sum of the strengths of all harmonic components to the strength of the fundamental frequency [11] [12]. THDv is a ratio of the sum of the RMS values of all voltage harmonic components up to a certain order to the RMS value of the fundamental voltage components.…”
Section: Total Harmonic Distortion (Thd)mentioning
confidence: 99%
“…The ratio of the sum of the RMS values of all harmonic components up to a certain order to the RMS values of the fundamental components. A measurement of a THD present in a signal is defined as the ratio of the sum of the strengths of all harmonic components to the strength of the fundamental frequency [11] [12]. THDv is a ratio of the sum of the RMS values of all voltage harmonic components up to a certain order to the RMS value of the fundamental voltage components.…”
Section: Total Harmonic Distortion (Thd)mentioning
confidence: 99%
“…Harmonics is an emerging power quality problem for both utilities and industries [15,16]. Harmonics is a sinusoidal component of a periodic wave or quantity taking a frequency that is an integral multiple of the fundamental frequency (power frequency) usually 50 or 60 Hz.…”
Section: Harmonics Analysismentioning
confidence: 99%
“…The system must maintain synchronization with the grid. The solar system was connected to a voltage source inverter to match the frequency levels and system rates, and the control diagram for the inverter was designed using a general PWM technique, and the reference signals were chosen from the grid parameters [10]. Currently, electric power systems are large and complex.…”