2019
DOI: 10.1016/j.bbmt.2019.05.021
|View full text |Cite
|
Sign up to set email alerts
|

Harmonization of Busulfan Plasma Exposure Unit (BPEU): A Community-Initiated Consensus Statement

Abstract: order, were area under the curve (AUC) in mM £ min, AUC in mg £ h/L, concentration at steady state (Css) in ng/ mL, AUC in mM £ h, and AUC in mg £ h/L. All respondents conceptually agreed on the ideal properties of a BPEU and to adopt a harmonized BPEU. Respondents were equally divided between selecting AUC in mM £ min versus mg £ h/L for harmonization. AUC in mg £ h/L was finally selected as the harmonized BPEU, because it satisfied most of the survey-determined ideal properties for the harmonized BPEU and is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
22
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 23 publications
(23 citation statements)
references
References 30 publications
1
22
0
Order By: Relevance
“…The results of the population pharmacokinetic model developed in the current investigation (Supplementary Material 1) were consistent with those previously reported: The value of 2.84h for the terminal half-life obtained in our case resulted remarkably similar to 2.77 h as reported elsewhere [6]. In addition, the values for CL (12.2 L/h/70Kg) and Vss (47.82L/70Kg) were in accordance with those reported by McCune et al [6] (11.4 L/h/70Kg and 43.8 L/70Kg, respectively).…”
Section: Accepted Articlesupporting
confidence: 92%
See 4 more Smart Citations
“…The results of the population pharmacokinetic model developed in the current investigation (Supplementary Material 1) were consistent with those previously reported: The value of 2.84h for the terminal half-life obtained in our case resulted remarkably similar to 2.77 h as reported elsewhere [6]. In addition, the values for CL (12.2 L/h/70Kg) and Vss (47.82L/70Kg) were in accordance with those reported by McCune et al [6] (11.4 L/h/70Kg and 43.8 L/70Kg, respectively).…”
Section: Accepted Articlesupporting
confidence: 92%
“…individualisation based on therapeutic drug monitoring (TDM) is feasible [9][10][11][12]. This fact is also applied to busulfan, for which TDM is currently done in the clinical setting [6]. In addition, the overall benefit risk and cost inform busulfan and treosulfan TDM feasibility.…”
Section: Accepted Articlementioning
confidence: 99%
See 3 more Smart Citations