Background
This study aimed to meta-analyze epidemiological data, revision rates, and incidences of different designs of a single Total Knee Arthroplasty System and compare these factors across different countries.
Methods
A systematic review was conducted on clinical studies and arthroplasty registries of ATTUNE TKA from 1999 to 2020. The main endpoints analyzed were revision rates and epidemiological data.
Results
The average age of patients was 67.8 years, with a gender distribution of 60% female and 40% male. The pooled average BMI was 29.4 kg/m2. Eight clinical studies showed a pooled revision rate per 100 observed CY of 0.5 (n = 1343 cases). Cumulative revision rates after 1, 3, and 5 years varied among registries, with the Swiss registry having the highest revision data (after 5 years: 6.3%) and the American registry having the lowest revision data (after 5 years: 1.7%). A comparison of the revision rates of mobile bearing and fixed bearing (41,200 cases) as well as cruciate retaining and posterior stabilized (n = 123,361 cases) showed no significant advantage in the first 5 years after implantation.
Conclusion
In conclusion, pooled data from 41,200 cases of TKA with a single Total Knee Arthroplasty System in two arthroplasty registries revealed that there was no significant difference in revision rates between the mobile bearing and fixed bearing design within the first 5 years after implantation. In addition, a comparison of the revision rates in n = 123,361 cases showed no significant advantage for cruciate retaining or posterior stabilized in the first 5 years after implantation.