Head-to-Head Comparison of Global and Regional Two-Dimensional Speckle Tracking Strain Versus Cardiac Magnetic Resonance Tagging in a Multicenter Validation Study

Abstract: The high accuracy against sonomicrometry and good agreement of global LS and global CS by 2DST and 2DTagg confirm the overall validity of 2DST strain measurement. Yet, higher intertechnique segmental variability and lower ability for detecting infarct suggest that 2DST strain estimates may be less performant on regional than on global basis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
1
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 54 publications
(38 citation statements)
references
References 26 publications
0
36
1
1
Order By: Relevance
“…It has been shown that strain, determined using either echocardiography or CMR, is a valuable parameter to determine the impact of coronary artery disease on heart function [12], to detect LV dysfunction, especially in patients with heart failure when EF is still preserved [1,4,12,23] and to reveal diffuse damage to the myocardium due to systemic diseases, such as cardiac amyloidosis [24,25], sarcoidosis [26] or cardiotoxic effects of chemotherapy [5]. Despite these many possible indications, the use of strain in clinical routine is still challenging due to the impact of intra-, interobserver- [7] and inter-vendor reproducibility of the different post-processing platforms [8,9,27] on strain results, which could also explain the lack of inter-technique agreement between echocardiography and CMR [28]. Therefore, before conducting studies to validate strain techniques in large patient cohorts, it is important to (1) identify the possible factors influencing strain results and to (2) minimize the impact of these factors.…”
Section: Discussionmentioning
confidence: 99%
“…It has been shown that strain, determined using either echocardiography or CMR, is a valuable parameter to determine the impact of coronary artery disease on heart function [12], to detect LV dysfunction, especially in patients with heart failure when EF is still preserved [1,4,12,23] and to reveal diffuse damage to the myocardium due to systemic diseases, such as cardiac amyloidosis [24,25], sarcoidosis [26] or cardiotoxic effects of chemotherapy [5]. Despite these many possible indications, the use of strain in clinical routine is still challenging due to the impact of intra-, interobserver- [7] and inter-vendor reproducibility of the different post-processing platforms [8,9,27] on strain results, which could also explain the lack of inter-technique agreement between echocardiography and CMR [28]. Therefore, before conducting studies to validate strain techniques in large patient cohorts, it is important to (1) identify the possible factors influencing strain results and to (2) minimize the impact of these factors.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, as opposed to speckle tracking, which also demonstrates excellent intra-observer and interobserver variability especially for GLS, 37 and tagging, validity of CMR FT has not been compared with phantom or animal work using the reference standard of sonomicrometry. 38 Despite the limitations of FT intervendor agreements, [16][17][18] the use of FT on bSSFP images is not subject to variability caused by different scanners or field strengths. 13 Noteworthy, this does not prove true for other quantification methods, such as native mapping techniques, which do not require specific reference values for software solutions available as in CMR-FT, but rather require them for each scanner and sequence.…”
Section: Agreementmentioning
confidence: 99%
“…13 One potential limitation is the lack of phantom or animal work using sonomicrometry as a basic science reference for deformation imaging validation; however, previous studies have reported good agreement of tagging with sonomicrometry. 38 Agreements were calculated for intertechnology and intervendor agreement on an intra-observer level, in the absence of interobserver agreement testing. However, analyses were performed by an experienced investigator in a core laboratory with previously shown high reproducibility also on the interobserver level.…”
Section: Study Limitationsmentioning
confidence: 99%
“…RV strain and strain rate values were initially evaluated using myocardial tagging technology (9). However, the laborious post-processing to extract and track the tagged lines on myocardium remains the major drawback of this tagging technology (10).…”
Section: Original Articlementioning
confidence: 99%
“…More recently, CMR cine image-based tissue tracking technology (CMR-TT) has allowed for a rapid and reliable quantification of myocardial deformation, with the advantage of high image quality unhindered by the availability of an adequate acoustic window (8)(9)(10). Normal ranges have been reported for left ventricular (LV) strain and strain rates using CMR-TT (8).…”
Section: Original Articlementioning
confidence: 99%