2015
DOI: 10.1021/acs.analchem.5b01850
|View full text |Cite
|
Sign up to set email alerts
|

Headspace versus Direct Immersion Solid Phase Microextraction in Complex Matrixes: Investigation of Analyte Behavior in Multicomponent Mixtures

Abstract: This work aims to investigate the behavior of analytes in complex mixtures and matrixes with the use of solid-phase microextraction (SPME). Various factors that influence analyte uptake such as coating chemistry, extraction mode, the physicochemical properties of analytes, and matrix complexity were considered. At first, an aqueous system containing analytes bearing different hydrophobicities, molecular weights, and chemical functionalities was investigated by using commercially available liquid and solid poro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
51
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

5
3

Authors

Journals

citations
Cited by 74 publications
(52 citation statements)
references
References 45 publications
0
51
0
1
Order By: Relevance
“…This is particularly important, as PDMS coatings are more robust, and have been applied to both ex vivo and in vivo samplings from tissues, 40 minimizing the occurrence of possible artifacts associated with the extraction process. 41 Due to the hydrophobic nature of the PDMS polymer, successful extraction of underivatized and short-chain aldehydes could prove to be difficult due to their polarity and relatively low concentrations. Consequently, the risk of losing important chemical information when sampling complex matrices with PDMS under underivatized conditions is high.…”
Section: Observation Of Volatile Aldehydes From Meat Using Gcxgc-tofmentioning
confidence: 99%
“…This is particularly important, as PDMS coatings are more robust, and have been applied to both ex vivo and in vivo samplings from tissues, 40 minimizing the occurrence of possible artifacts associated with the extraction process. 41 Due to the hydrophobic nature of the PDMS polymer, successful extraction of underivatized and short-chain aldehydes could prove to be difficult due to their polarity and relatively low concentrations. Consequently, the risk of losing important chemical information when sampling complex matrices with PDMS under underivatized conditions is high.…”
Section: Observation Of Volatile Aldehydes From Meat Using Gcxgc-tofmentioning
confidence: 99%
“…This feature is also referred to as balanced coverage. 6 Since analytes with higher logP values tend to have both higher K and Ka values, the reduced uptake rate forbids them from saturating the fiber coating. Figure 7.…”
Section: Effect Of Binding Matrix Components On Diffusive Samplingmentioning
confidence: 99%
“…In some cases, long extraction times may also cause sufficient accumulation of substances on the coating so as to initiate competition between analytes and/or interferences, leading to saturation and displacement effects. [4][5][6] Diffusive sampling is a method in which analytes are collected by an extraction phase (or, extractant) at a rate controlled by molecular diffusion of analytes through the diffusion boundary layer formed around the extractant in the sample matrix. 7,8 It has been shown previously that by exposing a SPME fiber directly to a sample matrix for a short period of time, diffusive sampling can be obtained.…”
Section: Introductionmentioning
confidence: 99%
“…A direct consequence of coating 90 saturation is inter-analyte competitive adsorption. This phenomenon was first studied for a two-component system, and recently 91 deeply investigated to interpret analyte behavior in complex matrices [8,9]. 92 In summary, a mathematical description of the phenomenon can be given by the following equation for a two-analyte system at where K A and K B are the adsorption equilibrium constants for the analytes A and B, and 97 represents the maximum concentration of active sites on the coating.…”
mentioning
confidence: 99%
“…99 Considering B as the analyte that induces coating saturation, it possible to notice that, when K B and are large enough to render the 100 term negligible, the amount of analyte A extracted at equilibrium will decrease when the concentration of saturating compound 101 B in the matrix is higher. Saturation of the coating, especially in complex mixtures, may eventually affect the HS-SPME mode more 102 than the DI-SPME mode [9]. This mainly relates to the mass-transfer resistance of the analytes at the interface of the HS/matrix and to 103 their Henry's law constants.…”
mentioning
confidence: 99%