2020
DOI: 10.1016/j.epsr.2019.106162
|View full text |Cite
|
Sign up to set email alerts
|

Health diagnosis scheme for in-service low voltage Aerial Bundled Cables using super-heterodyned airborne Ultrasonic testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 40 publications
0
9
0
Order By: Relevance
“…Acquired thermal data values from the failed cable are used as a reference in the reported study. 277 weeks was the recorded service life of this cable from date of installation [4].…”
Section: Case Studymentioning
confidence: 99%
See 1 more Smart Citation
“…Acquired thermal data values from the failed cable are used as a reference in the reported study. 277 weeks was the recorded service life of this cable from date of installation [4].…”
Section: Case Studymentioning
confidence: 99%
“…Despite abovementioned benefits, the reliability of in-service ABCs, when subjected to changing climatic conditions, is not precisely known yet [6]. ABCs are reported to have a shorter lifespan when subjected to severe environmental conditions in coastal areas [4,7]. The combined effect of high solar radiation intensity, high moisture content, and heavy electrical loads in coastal metropolises, stresses the insulation of ABCs.…”
Section: Introductionmentioning
confidence: 99%
“…Conductive cables are the main part of these lines, consisting of one or more stranded conductors, twisted from several wires of highly conductive metals. The conductive wires are usually made of aluminum [2][3][4][5][6][7][8][9]. The choice of aluminum is not only due to a number of reasons related to its physical properties, but also because of economic reasons [4,8].…”
Section: Introductionmentioning
confidence: 99%
“…The cores in a cable with several stranded cores are isolated from each other by jackets [2,11,12]. Depending on the environmental and operating conditions, cross-linked polyethylene with the addition of carbon black and titanium dioxide (XLPE cables) or special dense paper filled with either a viscous mixture of mineral oil and resin (massimpregnated cables) or liquid mineral oil (oil-filled cables) are used as a coating [2,12]. In the case of a single stranded conductor, either bare cables [3,4,6,9] or isolated ones [2,13] are used.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation