2022
DOI: 10.1016/j.jhin.2021.11.019
|View full text |Cite
|
Sign up to set email alerts
|

Healthcare-acquired clusters of COVID-19 across multiple wards in a Scottish health board

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 30 publications
0
10
0
Order By: Relevance
“…Current hospital architectural standards stipulate a minimum of 6 air changes per hour in clinical spaces, more in procedural and operative areas. This is considerably more air changes compared to the estimates associated with well-documented superspreading events in hospitals, nursing homes, hospices, restaurants, and churches [14,15,61–65]. Higher air changes are associated with less recovery of SARS-CoV-2 from the air in hospitalized patients’ rooms, faster clearance of respiratory aerosols, and less viral exposure for healthcare personnel [66 ▪▪ ,67,68].…”
Section: Structural Approaches To Preventionmentioning
confidence: 97%
“…Current hospital architectural standards stipulate a minimum of 6 air changes per hour in clinical spaces, more in procedural and operative areas. This is considerably more air changes compared to the estimates associated with well-documented superspreading events in hospitals, nursing homes, hospices, restaurants, and churches [14,15,61–65]. Higher air changes are associated with less recovery of SARS-CoV-2 from the air in hospitalized patients’ rooms, faster clearance of respiratory aerosols, and less viral exposure for healthcare personnel [66 ▪▪ ,67,68].…”
Section: Structural Approaches To Preventionmentioning
confidence: 97%
“…For a detailed description of the number of references at each stage, see the Prisma flowchart in figure 1. Overall, the 19 studies included here provide evidence for the effectiveness (or ineffectiveness) of the following NPIs: ventilation (n = 12) [10][11][12][13][14][15][16][17][18][19][20][21]; air filtration/air cleaning devices (n = 4) [17,[26][27][28]; surface disinfection (n = 5) [20][21][22][23][24]; room occupancy (n = 6) [11,12,16,[24][25][26]; and screens/barriers (n = 1) [17]. No evidence was found on the use of CO 2 monitoring or one-way systems in reducing transmission.…”
Section: Resultsmentioning
confidence: 99%
“…Unclear association : Three (of 12) studies considered ventilation in combination with a range of other NPIs (Li et al [10] Dancer et al [19] and Feathers et al [18]) and do not enable one to determine the effect of ventilation alone, although they provide an understanding of how different NPIs can work together to affect transmission. Li et al [10] found that in a residential setting increased ventilation (measured using normalCO2 tracer decay) in combination with lower adherence to masking (adherence qualitatively assessed) was associated with increased transmission.…”
Section: Resultsmentioning
confidence: 99%
“… 8 Regular opening of windows was instituted as an intervention in January 2021, given that most of the ward bedrooms relied on natural ventilation, but compliance was not formally audited. 10 Air extract for most rooms occurred through the ensuite toilet rather than within the room itself, which was often the only area where there was mechanical ventilation. The corridors have supplied filtered air resulting in positive pressure with respect to the wards.…”
Section: Discussionmentioning