2019
DOI: 10.1109/jsen.2019.2914166
|View full text |Cite
|
Sign up to set email alerts
|

Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
105
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 195 publications
(106 citation statements)
references
References 79 publications
1
105
0
Order By: Relevance
“…With the recent explosion of wearable tracker systems, wrist PPG devices have become the most popular alternative for consumer grade HR monitoring during physical activities. Despite their promising application in ambulatory environments ( [19]- [22]), in stationary conditions such as the ones this study focuses on, frequent arm motion could still corrupt the PPG signal more regularly than more steady PPG sensors placed in the head. In this context, we believe that the neck could be a favourable new location for clinical PPG.…”
mentioning
confidence: 99%
“…With the recent explosion of wearable tracker systems, wrist PPG devices have become the most popular alternative for consumer grade HR monitoring during physical activities. Despite their promising application in ambulatory environments ( [19]- [22]), in stationary conditions such as the ones this study focuses on, frequent arm motion could still corrupt the PPG signal more regularly than more steady PPG sensors placed in the head. In this context, we believe that the neck could be a favourable new location for clinical PPG.…”
mentioning
confidence: 99%
“…Motion is often an arbitrary and spontaneous behavior which can be rhythmic or non-rhythmic. The acquired PPG signals exhibit both MA spectral peaks that lie distant from HR spectral peak as well as overlapping ones, rendering them indistinguishable [148]. In the presence of rhythmic movements such as running and walking, the peak corresponding to MA might be close to the HR peak.…”
Section: • Motion Artifacts Removalmentioning
confidence: 99%
“…The simplest approach is to use a band-pass filter that can help to reduce the noise and eliminate the constant component of the signal. Such a solution is in common use [4]. However, the signal at the input of the filter can have significant changes of the constant component, as well as signal fluctuations caused by wrist movement, resulting in large peaks and oscillations at the output of the band-pass filter, as can be seen in Figure 2a As can be seen from the waveforms from Figure 1, the signal from the wrist is much weaker; moreover, each signal has a variable offset, and it contains noise and interference.…”
Section: Signal Conditioningmentioning
confidence: 99%
“…Heart rate estimation from wrist PPG is now a popular area of investigation, and many algorithms for such a task have been proposed [4]. Some of them require significant computing power and memory usage, blocking their application in small portable low-power devices.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation