Abstract:To examine the influence of the distance between adjacent implant osteotomies on heat accumulation in the inter-osteotomy area, two experimental groups with 15 pairs of osteotomies in Type II polyurethane blocks were compared: 7 mm inter-osteotomy separations (Group A, n = 15) and 14 mm inter-osteotomy separations (Group B, n = 15). An infrared thermographic analysis of thermal changes in the inter-osteotomy area was completed. A one-way analysis of variance (ANOVA) and Fisher post-test were used to determine … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.