Heat and mass transfer analysis in single cell of PEFC using different PEM and GDL at higher temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
30
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 19 publications
(31 citation statements)
references
References 20 publications
1
30
0
Order By: Relevance
“…According to the pre-experiment, the impact of the observation window on the power generation performance can be ignored. In this pre-experiment, the initial temperature was set to 343 K, and the RHs of supply gases of the anode and cathode were 80%RH with and without a hole for the purpose of temperature measurement observations [27,28]. According to this pre-experiment, we confirmed voltage drops caused by observation window at the current (load) density of 0.80 A/cm 2 during anode and cathode observation tests of only 4% and 7%, respectively.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 66%
See 2 more Smart Citations
“…According to the pre-experiment, the impact of the observation window on the power generation performance can be ignored. In this pre-experiment, the initial temperature was set to 343 K, and the RHs of supply gases of the anode and cathode were 80%RH with and without a hole for the purpose of temperature measurement observations [27,28]. According to this pre-experiment, we confirmed voltage drops caused by observation window at the current (load) density of 0.80 A/cm 2 during anode and cathode observation tests of only 4% and 7%, respectively.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 66%
“…Table 1 shows the specifications of cell components of the single cells of PEFC used in this study. Figure 1 shows the experimental procedure and cell structure used to measure the temperature [22,23,27,28]. The current collector and end plate had a hole measuring 50 mm × 50 mm, which was used to measure temperature via thermographs, having the same size as the electrode.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…Mass transport phenomena in a cell such as distributions of H 2 , O 2 , and H 2 O concentration are also being investigated [12][13][14]. The temperature distribution on the back of the separator and the interface between PEM and the cathode catalyst layer has been investigated experimentally [15,16] and numerically [17,18], respectively, by the authors. Though the current density and temperature distribution were studied experimentally [19] and numerically [20] at the same time, there have been no reports investigating the distribution of H 2 , O 2 , H 2 O concentration and current density on the interface between PEM and the anode catalyst layer, where the H 2 oxidation reaction occurs or the interface between PEM and the cathode catalyst layer where the O 2 reduction reaction occurs.…”
Section: Introductionmentioning
confidence: 99%
“…However, most of the studies involving the impacts of RH on PEMFC are limited to less than 80 • C. Studies on this subject at higher temperatures (over 80 • C) have seldomly been published. Nishimura et al [16,17] focused on the temperature distribution in a single PEMFC and used a thermograph to investigate the impact of RH and GDL thickness on the in-plane temperature distribution of the separator backside. Akitomo et al [18] provided a solution to solve the problem resulting from the reduced oxygen pressure in the high temperature (100 • C) by pressurizing gas.…”
Section: Introductionmentioning
confidence: 99%