Heat Transfer Performance of Internal Cooling Channel With Single-Row Jet Impingement Array by Varying Flow Rates

Abstract: The current detailed experimental study focuses on the optimization of heat transfer performance through jet impingement by varying the coolant flow rate to each individual jet. The test section consists of an array of jets, each jet individually fed and metered separately, that expel coolant into the channel and exit through one end. The diameter D, height-to-diameter H/D, and jet spacing-to-diameter S/D are all held constant at 9.53 mm, 2, and 4, respectively. Upon defining the optimum flow rate for each jet… Show more