1990
DOI: 10.1039/ja9900500697
|View full text |Cite
|
Sign up to set email alerts
|

Helium-argon inductively coupled plasma for plasma source mass spectrometry

Abstract: An He -Ar mixed gas inductively coupled plasma (ICP) was investigated for use as an ion source for plasma mass spectrometry (MS). The addition of He to Ar produces a plasma capable of ionising high ionisation potential elements more efficiently than the pure Ar plasma. The best signal to noise ratios for metallic elements were obtained with a 20% He plasma, and for halides with a 30% He plasma. The He -Ar mixed gas plasma shows an improvement of one order of magnitude in the detection limits of several metalli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0

Year Published

1992
1992
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(20 citation statements)
references
References 7 publications
0
20
0
Order By: Relevance
“…Mass spectral interferences resulting from argon polyatomic species are reduced when He-based plasmas are applied as ionization sources, because He essentially is monoisotopic, and occurs at a low mass [11,12,20,24,25,27,30,35,36,[39][40][41][42]. The three isotopes of Ar ( 36 Ar + , 38 Ar + , and 40 Ar + ) along with polyatomic species containing Ar such as 40 Ar 16 O + , 40 Ar 40 Ar + , 40 Ar 35 Cl + interfere with the determination of certain isotopes, e.g.…”
Section: Potentials and Drawbacks Of Helium Icp Dischargesmentioning
confidence: 99%
“…Mass spectral interferences resulting from argon polyatomic species are reduced when He-based plasmas are applied as ionization sources, because He essentially is monoisotopic, and occurs at a low mass [11,12,20,24,25,27,30,35,36,[39][40][41][42]. The three isotopes of Ar ( 36 Ar + , 38 Ar + , and 40 Ar + ) along with polyatomic species containing Ar such as 40 Ar 16 O + , 40 Ar 40 Ar + , 40 Ar 35 Cl + interfere with the determination of certain isotopes, e.g.…”
Section: Potentials and Drawbacks Of Helium Icp Dischargesmentioning
confidence: 99%
“…Finally, helium is of small size and light mass, so it easily diffuses into the plasma and collides with polyatomic ions. These collisions could result in the dissociation of polyatomic ions and the reduction of background signals [15]. For polyatomic ions that are weakly bound, they are easy to be fragment during collision processes.…”
Section: Resultsmentioning
confidence: 99%
“…It has great benefits; where it produces plasma to induce the ionization of some elements which have a high ionization potential efficiently more than the Argon gas only and also. The mixture of Argon and Helium show an improvement in detection limits for several elements [44].…”
Section: Reagents and Handling Proceduresmentioning