Helium radiography with a digital tracking calorimeter—a Monte Carlo study for secondary track rejection

Abstract: Radiation therapy using protons and heavier ions is a fast-growing therapeutic option for cancer patients. A clinical system for particle imaging in particle therapy would enable online patient position verification, estimation of the dose deposition through range monitoring and a reduction of uncertainties in the calculation of the relative stopping power of the patient.Several prototype imaging modalities offer radiography and computed tomography using protons and heavy ions. A Digital Tracking Calorimeter (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 60 publications
2
8
0
Order By: Relevance
“…The precision values from other studies are at maximum 40% better than the measured mean WET precision of 1.55% of this work. Considering the dE measurement of this work is performed within 300𝜇m silicon, while the residual energy and/or range is measured in detection systems with thicknesses above 250 mm, 23,25 the observed WET precision is surprisingly close to the best precision achieved until now. Furthermore, the comparison shows that an extension of the WET range toward WETs below 280.58 mm should not be performed using the same initial energy, since the WET precision deteriorates quickly.…”
Section: 23supporting
confidence: 60%
See 4 more Smart Citations
“…The precision values from other studies are at maximum 40% better than the measured mean WET precision of 1.55% of this work. Considering the dE measurement of this work is performed within 300𝜇m silicon, while the residual energy and/or range is measured in detection systems with thicknesses above 250 mm, 23,25 the observed WET precision is surprisingly close to the best precision achieved until now. Furthermore, the comparison shows that an extension of the WET range toward WETs below 280.58 mm should not be performed using the same initial energy, since the WET precision deteriorates quickly.…”
Section: 23supporting
confidence: 60%
“…For a simulation study about helium‐ion imaging with a tracking calorimeter, which also includes higher WET ranges up to ∼310 mm, a simulated helium‐ion precision as low as 0.9% for the same WET range of (280.86 and 299.8 mm) can be extracted 25 …”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations