Hemodynamic Performance and Durability of Mosaic Bioprostheses for Aortic Valve Replacement, up to 13 Years

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 25 publications
1
9
0
Order By: Relevance
“…Valve design and implantation technique have been developed to enhance mechanical wear and stress absorption properties, being further supported by its supraannular position. In our series, 10year survival free of SVD (90.8%) and free of reoperation due to SVD (91.9%) was consistent with results of conventional stented valves in patients of comparable age, which is approximately 90% [10,[19][20][21][22] (Table 3 and Fig 5).…”
Section: Commentsupporting
confidence: 86%
“…Valve design and implantation technique have been developed to enhance mechanical wear and stress absorption properties, being further supported by its supraannular position. In our series, 10year survival free of SVD (90.8%) and free of reoperation due to SVD (91.9%) was consistent with results of conventional stented valves in patients of comparable age, which is approximately 90% [10,[19][20][21][22] (Table 3 and Fig 5).…”
Section: Commentsupporting
confidence: 86%
“…Of the 93 studies, 51 proved at overall low risk of bias. 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 Twenty one of the remaining 42 proved at overall moderate risk of bias 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 and 21 at overall high risk of bias. 90 91 92 93 94 95 …”
Section: Resultsmentioning
confidence: 99%
“…Twelve studies 21 22 25 26 27 33 53 68 69 81 85 90 with published Kaplan-Meier curves including 7603 patients reported on structural valve deterioration after SAVR. Supplementary appendix F presents the definition for structural valve deterioration across all 12 studies.…”
Section: Resultsmentioning
confidence: 99%
“…When hemodynamics and durability were compared with the data for Mosaic (Medtronic Inc., Minneapolis, MN, USA) published by the National Cerebral and Cardiovascular Center, the data were comparable. 22 Fiegl et al reported no significant difference in LVM regression or PPM with CEPM Ease or the St. Jude Medical Trifecta (SJM Trifecta; St. Jude Medical, St. Paul, MN, USA) bioprostheses, even though the SJM Trifecta had a lower mean PG at the early postoperative and 1-year evaluations, as well as a higher EOA and EOAI in the early postoperative period. 23 Ruzicka et al reported that the CEPM showed the lowest mean PG of 5 bioprostheses evaluated (CEPM, Mosaic, Mosaic Ultra, Epic Supra, Sorin Soprano) and larger EOAs than the porcine bioprostheses.…”
Section: Lvm Regression In Patients With Isolated Avr: Comparison Amomentioning
confidence: 99%