The SAGES Manual of Hernia Surgery 2018
DOI: 10.1007/978-3-319-78411-3_4
|View full text |Cite
|
Sign up to set email alerts
|

Hernia Materials: Fundamentals of Prosthetic Characteristics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 59 publications
0
4
0
Order By: Relevance
“…In the 1940s, silver and tantalum meshes were introduced for hernia repair applications [1,2], and by the late-1950s, permanent synthetic polymer meshes were utilized [3]. In the decades following, more than 150 unique designs have been developed, comprised of permanent synthetic polymers, biological tissue-derived materials, and most recently, resorbable polymers [4,5].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the 1940s, silver and tantalum meshes were introduced for hernia repair applications [1,2], and by the late-1950s, permanent synthetic polymer meshes were utilized [3]. In the decades following, more than 150 unique designs have been developed, comprised of permanent synthetic polymers, biological tissue-derived materials, and most recently, resorbable polymers [4,5].…”
Section: Introductionmentioning
confidence: 99%
“…Devices in this category are comprised of: poly-4hydroxybutyrate (Phasix TM Mesh, Becton, Dickinson and Company (BD), Franklin Lakes, NJ), ultra-pure fibroin derived from silk (SeriV R Surgical Scaffold, Sofregen Medical), polyglycolic acid (SafilV R Mesh, B Braun), a copolymer of glycolide and lactide (Dexon TM Mesh, Covidien & Vicryl TM Knitted Mesh, Ethicon, Inc.), a co-polymer of polyglycolic acid and trimethylene carbonate (GoreV R Bio-AV R Tissue Reinforcement, W.L. Gore & Assoc., Inc.), and a co-polymer of glycolide, lactide, and trimethylene carbonate (TIGRV R Matrix Surgical Mesh, Insightra Medical) [4,5].…”
Section: Introductionmentioning
confidence: 99%
“…The suture pull out test, which is used to determine the suture tearing out resistance of surgical knitted meshes with suture threads, is a crucial test for the final implantation of the mesh inside the human body, proving the effective fixation of the implant. Moreover, the suture pull out strength is recommended in the literature to be 20 N. 32 The suture pull out strength of the mesh must be greater than this value to ensure safe fixation. Therefore, centered points were marked at a distance of 2 mm to the longer cutting edge, while, for the latter, the marking was in the third undamaged knitting loop (counted from the cutting edge) in the center of the longitudinal cut on each side.…”
Section: Methodsmentioning
confidence: 99%
“…The suture pull out test, which is used to determine the suture tearing out resistance of surgical knitted meshes with suture threads, is a crucial test for the final implantation of the mesh inside the human body, proving the effective fixation of the implant. Moreover, the suture pull out strength is recommended in the literature to be 20 N . The suture pull out strength of the mesh must be greater than this value to ensure safe fixation.…”
Section: Methodsmentioning
confidence: 99%