2023
DOI: 10.1016/j.jchromb.2022.123569
|View full text |Cite
|
Sign up to set email alerts
|

Heterogeneity and lyophilization comparison of stool processing for gastrointestinal bile acid measurement by LC-MS/MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…At the same time, it is important to mention that lyophilization requires special equipment and elongates the sample processing time. The interchangeability of fresh and lyophilized feces samples was studied [153], demonstrating that the measured BA concentrations were comparable for original and lyophilized samples. Original, fresh feces can be a suitable matrix for BAs analysis except for in detailed investigations of trace bile acids.…”
Section: Matrices To Be Analyzed For Bile Acid Compositionmentioning
confidence: 88%
See 1 more Smart Citation
“…At the same time, it is important to mention that lyophilization requires special equipment and elongates the sample processing time. The interchangeability of fresh and lyophilized feces samples was studied [153], demonstrating that the measured BA concentrations were comparable for original and lyophilized samples. Original, fresh feces can be a suitable matrix for BAs analysis except for in detailed investigations of trace bile acids.…”
Section: Matrices To Be Analyzed For Bile Acid Compositionmentioning
confidence: 88%
“…BAs are frequently measured from lyophilized feces instead of fresh ones [10,28,52,65,67,83,89,90,94,101,103,109,111,115,116,149,151,[153][154][155][156][157][158], thus expressing the BA concentrations based on the dry weight of the lyophilizate. At the same time, it is important to mention that lyophilization requires special equipment and elongates the sample processing time.…”
Section: Matrices To Be Analyzed For Bile Acid Compositionmentioning
confidence: 99%
“…That study utilized lyophilized homogenized fecal samples and an untargeted metabolomic approach which is not optimized to detect BAs [ 169 ]. It is important to note that upstream sample handling can impact metabolite concentrations, and the process of lyophilization prior to targeted fecal BA metabolomics in humans was recently shown to increase BA concentrations by about two- to four-fold compared to non-lyophilized feces when then assessed via LC-MS/MS [ 170 ]. This thus highlights the importance of consistent methods of performing targeted metabolomics and the importance of understanding the employed methods.…”
Section: Feline Microbial-derived Bile Acidsmentioning
confidence: 99%