1994
DOI: 10.1007/978-1-4615-2468-7_75
|View full text |Cite
|
Sign up to set email alerts
|

Heterogeneity and Stability of Local PO2 Distribution within the Brain Tissue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
24
0
2

Year Published

1996
1996
2005
2005

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 51 publications
(31 citation statements)
references
References 12 publications
5
24
0
2
Order By: Relevance
“…Therefore, our electrodes measure CBF and PO 2 in a region containing B1,000 microvessels. We confirmed that CBF and PO 2 are recorded from the same brain region in initial experiments in which both Pt electrodes in one hemisphere recorded only PO 2 or only CBF (Figures 1C and 1B).In the PO 2 distributions around microvessels found by others using polarographic microelectrodes (typically o25 mm in diameter), values near zero coexist with those near that of arterial blood (Feng et al, 1988;Lü bbers et al, 1994;Erecinska and Silver, 2001). Our 100 mm diameter electrodes however, with conical sensing surfaces of about 0.9 mm 2 , integrate PO 2 measurements from all sites in a tissue volume of 0.58 mm 3 .…”
supporting
confidence: 86%
See 2 more Smart Citations
“…Therefore, our electrodes measure CBF and PO 2 in a region containing B1,000 microvessels. We confirmed that CBF and PO 2 are recorded from the same brain region in initial experiments in which both Pt electrodes in one hemisphere recorded only PO 2 or only CBF (Figures 1C and 1B).In the PO 2 distributions around microvessels found by others using polarographic microelectrodes (typically o25 mm in diameter), values near zero coexist with those near that of arterial blood (Feng et al, 1988;Lü bbers et al, 1994;Erecinska and Silver, 2001). Our 100 mm diameter electrodes however, with conical sensing surfaces of about 0.9 mm 2 , integrate PO 2 measurements from all sites in a tissue volume of 0.58 mm 3 .…”
supporting
confidence: 86%
“…In the PO 2 distributions around microvessels found by others using polarographic microelectrodes (typically o25 mm in diameter), values near zero coexist with those near that of arterial blood (Feng et al, 1988;Lü bbers et al, 1994;Erecinska and Silver, 2001). Our 100 mm diameter electrodes however, with conical sensing surfaces of about 0.9 mm 2 , integrate PO 2 measurements from all sites in a tissue volume of 0.58 mm 3 .…”
Section: Advantages and Limitations Of Cerebral Blood Flow-oxygen Tenmentioning
confidence: 85%
See 1 more Smart Citation
“…This fell to about 40 mm Hg when the arterial oxygen pressures were decreased to about 90 mm Hg (low normal). Both oxygen extraction and the resulting vascular oxygen pressures were similar to those found, for example, in brain cortex (Silver, 1977;Lubbers, 1994;Olano et al 1995). The oxygen pressures measured by phosphorescence quenching were more consistent with those of Whalen and Nair (1977;1983) as the extravascular oxygen pressures might be expected to be below those in the microcirculation by 5-10 mm Hg.…”
Section: 2supporting
confidence: 71%
“…Thus, it was possible to study oxygen transport and consumption in tissue by determining local p o 2 in vivo. Measurements of this kind have been performed, e.g., in brain [7], heart [8], kidney [9], liver, eye, ear [10]. Another example of application of the oxygen needle electrode is the investigation of the effect of cancer inhibitors on oxygen transport in tumors.…”
Section: Applications In Physiology and Medicinementioning
confidence: 99%