2020 42nd Annual International Conference of the IEEE Engineering in Medicine &Amp; Biology Society (EMBC) 2020
DOI: 10.1109/embc44109.2020.9175161
|View full text |Cite
|
Sign up to set email alerts
|

High Accuracy Respiration and Heart Rate Detection Based on Artificial Neural Network Regression

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
25
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(25 citation statements)
references
References 7 publications
0
25
0
Order By: Relevance
“…Continuous vital signs monitoring can prevent life-threatening scenarios by providing early warnings before a decline of the patient's status [104]. In this sub-category of papers on value estimation we include papers dealing with the estimation of vital signs, such as HR (n = 21) [17], [22], [25], [28], [29], [52], [55]- [57], [62], [64], [74], [76], [82], [87], [91], [93], [96]- [98], BR [58], [66], [88], [89], [99], [102] (n = 6), both HR and BR [31], [34], [40], [53], [54], [92], [103] (n = 7), BP [65], [67], [75], [83], [85], [100], [101] (n = 7), oxygen saturation (SpO2) [84] (n = 1), and spyrometric indices [61] (n = 1) in a given windows of observation.…”
Section: A First Cluster Tasksmentioning
confidence: 99%
See 1 more Smart Citation
“…Continuous vital signs monitoring can prevent life-threatening scenarios by providing early warnings before a decline of the patient's status [104]. In this sub-category of papers on value estimation we include papers dealing with the estimation of vital signs, such as HR (n = 21) [17], [22], [25], [28], [29], [52], [55]- [57], [62], [64], [74], [76], [82], [87], [91], [93], [96]- [98], BR [58], [66], [88], [89], [99], [102] (n = 6), both HR and BR [31], [34], [40], [53], [54], [92], [103] (n = 7), BP [65], [67], [75], [83], [85], [100], [101] (n = 7), oxygen saturation (SpO2) [84] (n = 1), and spyrometric indices [61] (n = 1) in a given windows of observation.…”
Section: A First Cluster Tasksmentioning
confidence: 99%
“…For the hybrid architecture the deep learning model used was an encoder-decoder type in combination with extracted features from K-nearest neighbour. The general [17], [22], [25], [28], [29], [31], [34], [40], [52]- [58], [61], [62], [64]- [67], [74]- [76], [82]- [89], [91]- [93], [96]- [103] Signal reconstruction (n = 18)…”
Section: A First Cluster Tasksmentioning
confidence: 99%
“…Radar systems can monitor RR by using frequency-modulated continuous-wave (FMCW) to observe Doppler shifts associated with breathing movements, and have been able to obtain accuracy of 99% (Tsai et al, 2020). FMCW radar works by transmitting frequency modulated pulses, i.e., pulses with periodic shifts in frequency, and the received echos undergo respective frequency shifts due to the motion of the body, known as the Doppler effect.…”
Section: Respiratory Ratementioning
confidence: 99%
“…Simultaneously, an increasing number of researchers are focusing on HR signal estimation using DL methods. Various approaches to measuring HR using artificial neural networks (ANN) have been proposed [ 11 ], and the majority of the methods contribute to reducing the noise in order to obtain an accurate HR number. A considerable number of researchers focus on the automatic pathological classifications of ECGs [ 12 , 13 ], and there are still a few researchers working on improving the performance of conventional methods.…”
Section: Introductionmentioning
confidence: 99%