2016
DOI: 10.1039/c6ee02027e
|View full text |Cite
|
Sign up to set email alerts
|

High current density, long duration cycling of soluble organic active species for non-aqueous redox flow batteries

Abstract: Symmetric flow cell cycling of a soluble phenothiazine.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

8
305
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 222 publications
(314 citation statements)
references
References 64 publications
8
305
1
Order By: Relevance
“…The active species concentrations were 5 mM and 10 mM for CV and UME experiments, respectively. A coiled platinum wire (BASi) served as the counter 28 CV measurements utilized a 3 mm diameter glassy carbon working electrode (BASi) and were collected using a Biologic VMP3 potentiostat with 100% solution resistance compensation (iR-correction). The 3 mm glassy carbon electrode was prepared by rinsing with DI H 2 O, polishing with 5 μm alumina suspension, sonicating for 1 min, and then rinsing with DI H 2 O a second time.…”
Section: Vomentioning
confidence: 99%
See 2 more Smart Citations
“…The active species concentrations were 5 mM and 10 mM for CV and UME experiments, respectively. A coiled platinum wire (BASi) served as the counter 28 CV measurements utilized a 3 mm diameter glassy carbon working electrode (BASi) and were collected using a Biologic VMP3 potentiostat with 100% solution resistance compensation (iR-correction). The 3 mm glassy carbon electrode was prepared by rinsing with DI H 2 O, polishing with 5 μm alumina suspension, sonicating for 1 min, and then rinsing with DI H 2 O a second time.…”
Section: Vomentioning
confidence: 99%
“…[20][21][22][23][24][25][26] Even fewer studies have incorporated advanced flow cell designs to minimize area specific resistance (ASR) and increase area specific power density. 21,[27][28][29] At present, reported NAqRFBs exhibit inadequate performance and durability, 8 but identifying performance limiting factors can be difficult because shortcomings could be attributed to active species degradation (e.g., instability, insolubility, chemical incompatibility), insufficient separator selectivity (e.g., crossover, low conductivity), or poor cell design (e.g., slow mass transfer, resistive electrodes, high pressure drop). 27 Due to the plethora and complexity of engineering challenges facing NAqRFBs, recent reports identify a range of performance-limiting factors, including active species stability, 8 electrode catalysts, 10 separator ASR, 30 or mass transfer rates.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…[43][44][45] Backing plates were machined from propylene. Inter-digitated flow fields were machined from 3.18 mm thick impregnated graphite (G347B graphite, MWI, Inc.) with 7 channels (1 mm wide × 0.5 mm deep), 4 inlets and 3 outlets.…”
Section: A2040mentioning
confidence: 99%
“…species. 15,16 In the present study, we further develop the method with experimental variations that provide more specific information about possible causes of capacity fade.…”
mentioning
confidence: 99%