Abstract:A parameter identification technique of an underlying bubble model of an experimentally observed single bubble in a cluster under dual-frequency external forcing is presented. The measurements are carried out via high-speed camera recordings at a rate of 162750 frames per second. The used frequencies during the experiment are 25 kHz and 50 kHz. With a digital image processing technique, the measured bubble radius as a function of time is determined. The employed governing equation for the parameter fitting is … Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.