2008
DOI: 10.1097/icl.0b013e31815b7d91
|View full text |Cite
|
Sign up to set email alerts
|

High-Dk Piggyback Contact Lenses Over Intacs for Keratoconus: A Case Report

Abstract: Patients with Intacs for keratoconus may require a combination of soft and rigid contact lenses for the best possible VA. Contact lens fitting with a high-Dk piggyback contact lens system can provide optimal comfort, corneal health, and VA for patients with Intacs for keratoconus.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
16
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(17 citation statements)
references
References 19 publications
1
16
0
Order By: Relevance
“…[2122242526] However, the greatest flattening effect of the ring segment is exerted on the mid-peripheral region of the cornea directly over the ICRS which creates an abnormal artificial steepening of the peripheral cornea relative to the mid-periphery; this can make RGP fitting difficult. [151617]…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…[2122242526] However, the greatest flattening effect of the ring segment is exerted on the mid-peripheral region of the cornea directly over the ICRS which creates an abnormal artificial steepening of the peripheral cornea relative to the mid-periphery; this can make RGP fitting difficult. [151617]…”
Section: Discussionmentioning
confidence: 99%
“…[1516173031] There is only one case report of MSD contact lens fitting in advanced keratoconus with INTACS. Recently, Dalton and Sorbara described one patient with keratoconus who was successfully fitted with a mini scleral contact lens for residual refractive error after ICRS surgery.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Later, Smith & Carre [22] all discussed the fit of a high DK/t Paflufocon B (58) rigid gas permeable lens on a pure vision disposable soft contact lens in a piggyback system that was well tolerated by an advanced stage keratoconus patient having implanted Intacs. The disposable soft contact lens was easily replaced to compensate for the fluctuations in refractive error.…”
Section: Clinical Aspects Of the Piggyback Systemmentioning
confidence: 99%
“…Irregular high corneal astigmatism can be seen in keratoconus, 4 pellucid marginal degeneration, 5 keratoplasty, 6 post-LASIK ectasia 7 and corneal ring segment implantation. 8 These conditions lead to poor visual acuity with glasses or conventional soft contact lenses. Rigid gas-permeable (RGP) contact lenses are considered the best optical solution for patients with irregular corneas for its masking corneal irregularity and optical aberration by creating a tear layer between the lens and the cornea.…”
mentioning
confidence: 99%