High-efficiency in situ resonant inelastic x-ray scattering (iRIXS) endstation at the Advanced Light Source

Abstract: An endstation with two high-efficiency soft x-ray spectrographs was developed at Beamline 8.0.1 of the Advanced Light Source, Lawrence Berkeley National Laboratory. The endstation is capable of performing soft x-ray absorption spectroscopy, emission spectroscopy, and, in particular, resonant inelastic soft x-ray scattering (RIXS). Two slit-less variable line-spacing grating spectrographs are installed at different detection geometries. The endstation covers the photon energy range from 80 to 1500 eV. For study… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
150
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

6
3

Authors

Journals

citations
Cited by 126 publications
(150 citation statements)
references
References 40 publications
0
150
0
Order By: Relevance
“…RIXS maps the fluorescence intensity as a function of both absorption and emission energy 64 , revealing the energy distribution buried in the features observed through STXM-XAS. Rapid acquisition of such extensive RIXS maps was only made possible by the recent commission of ultra-high efficiency RIXS systems 65 . The Supplementary Information includes a detailed discussion of the RIXS features, with the relevant details summarized here.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…RIXS maps the fluorescence intensity as a function of both absorption and emission energy 64 , revealing the energy distribution buried in the features observed through STXM-XAS. Rapid acquisition of such extensive RIXS maps was only made possible by the recent commission of ultra-high efficiency RIXS systems 65 . The Supplementary Information includes a detailed discussion of the RIXS features, with the relevant details summarized here.…”
Section: Resultsmentioning
confidence: 99%
“…Soft X-ray RIXS maps (and conventional TEY and TFY XAS spectra) were collected in the newly commissioned ultra-high efficiency iRIXS endstation at Beamline 8.0.1 of the ALS 65 . All the samples were processed in glove box with high purity Ar environment, and the mounted samples were sealed and transferred into the experimental vacuum chamber through a specially designed sample transfer kit 78 .…”
Section: Methodsmentioning
confidence: 99%
“…RIXS maps were collected in the newly commissioned ultrahigh efficiency iRIXS endstation at Beamline 8.0.1 at the Advanced Light Sources. 72 All the cycled electrodes were immediately harvested from the cells at designated cutoff voltages to minimize the side reactions between cycled electrodes and electrolyte and vigorously washed by DMC solvents to ensure the removal of soluble surface species. All the dried electrodes were transferred into the experimental vacuum chamber through a specially designed sample transfer kit in an Ar-filled glove box to avoid any air exposure.…”
Section: Methodsmentioning
confidence: 99%
“…Soft X-ray absorption spectroscopy was performed in the iRIXS endstation at Beamline 8.0.1 of the Advanced Light Source in LBNL 42 . Electrode samples were loaded into the ultra-high vacuum sXAS characterization chamber with a special sample transfer kit to avoid any air exposure effects.…”
Section: Methodsmentioning
confidence: 99%