2015
DOI: 10.1093/ijlct/ctv002
|View full text |Cite
|
Sign up to set email alerts
|

High-efficiency ventilation and heating systems by means of solar air collectors for industry building refurbishment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 1 publication
0
7
0
Order By: Relevance
“…It is instructive to review the outcomes of a3 -month energy metering of the heat actually generated by a1 3.1 2.2 m 2 (width height)t ranspired solar air collector installed in 2013 on the south faÅadeofatest building in Lucerne,corresponding to Switzerlandsa verage-sized industrial building with thermally insulated roof and walls (useful floor area: 300 m 2 ;h eight:8 .2 m). [26] Them easurements lasted from November 27th, 2013 to February 28th, 2014, and the results were unequivocal. Thet emperature of the air delivered by the unglazed collector typically was 30 8C, with typical values of thermal efficiency primarily depending on irradiance,o utside temperature,a ir volumef low,a nd wind speeda nd direction, reaching6 0%,w hich is in good agreement with previous results.…”
Section: Unglazed Collectorsmentioning
confidence: 84%
See 3 more Smart Citations
“…It is instructive to review the outcomes of a3 -month energy metering of the heat actually generated by a1 3.1 2.2 m 2 (width height)t ranspired solar air collector installed in 2013 on the south faÅadeofatest building in Lucerne,corresponding to Switzerlandsa verage-sized industrial building with thermally insulated roof and walls (useful floor area: 300 m 2 ;h eight:8 .2 m). [26] Them easurements lasted from November 27th, 2013 to February 28th, 2014, and the results were unequivocal. Thet emperature of the air delivered by the unglazed collector typically was 30 8C, with typical values of thermal efficiency primarily depending on irradiance,o utside temperature,a ir volumef low,a nd wind speeda nd direction, reaching6 0%,w hich is in good agreement with previous results.…”
Section: Unglazed Collectorsmentioning
confidence: 84%
“…It is instructive to review the outcomes of a 3‐month energy metering of the heat actually generated by a 13.1×2.2 m 2 (width×height) transpired solar air collector installed in 2013 on the south façade of a test building in Lucerne, corresponding to Switzerland's average‐sized industrial building with thermally insulated roof and walls (useful floor area: 300 m 2 ; height: 8.2 m) . The measurements lasted from November 27th, 2013 to February 28th, 2014, and the results were unequivocal.…”
Section: Technology Applications In the Building Environmentmentioning
confidence: 99%
See 2 more Smart Citations
“…Despite the fact that there are many TSC installations across Europe, there is a significant lack of independently tested monitoring data of TSC performance available for different sites, as mentioned by various researchers, such as Brown et al [14] in UK and Sicre and Baumann [19] in Switzerland. The current study provides transpired solar collector researchers with yet missing information by presenting simulated results different Turkish climatic zones compared to data from the monitored TSC system of an industrial building near Istanbul.…”
Section: Ay and Khanlarimentioning