2020
DOI: 10.1016/j.sab.2020.105996
|View full text |Cite
|
Sign up to set email alerts
|

High enhancement factor in low-power unipolar discharge arc assisted laser induced plasma spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…The discharge arc pre-ionizes the sample surface before the pulsed laser reaches the sample surface, and intensies the lattice vibration, thereby reducing the laser excitation threshold. 37 In addition, the TCD can cause an increase in the sample temperature, reduce the reectivity of the sample surface, 38 increase the coupling efficiency between the sample and the pulsed laser, and increase the ablation mass of the sample, resulting in an enhancement in spectral intensity. 38,39 3.2 Effect of discharge length molecular bands have the same trend as Al(I) 396.1 nm and AlO (0-0).…”
Section: Emission Spectramentioning
confidence: 99%
“…The discharge arc pre-ionizes the sample surface before the pulsed laser reaches the sample surface, and intensies the lattice vibration, thereby reducing the laser excitation threshold. 37 In addition, the TCD can cause an increase in the sample temperature, reduce the reectivity of the sample surface, 38 increase the coupling efficiency between the sample and the pulsed laser, and increase the ablation mass of the sample, resulting in an enhancement in spectral intensity. 38,39 3.2 Effect of discharge length molecular bands have the same trend as Al(I) 396.1 nm and AlO (0-0).…”
Section: Emission Spectramentioning
confidence: 99%
“…(1) Spectra standardization Firstly, the spectra baseline can be well-tted and subtracted with a simple window-shiing method, which segments and ts the spectrum by the cubic spline interpolation, as described in our previous works. 37,38 Subsequently, the normalized spectral intensity is obtained by the ratio of the baseline corrected spectra to the area under baseline in the corresponding channel.…”
Section: Data Pretreatment and Standardizationmentioning
confidence: 99%
“…Nowadays, laser-induced micro-explosion technology 14,15 including laser-induced plasma spectroscopy (LIPS) [16][17][18][19] and laser-induced air shock from energetic materials (LASEM) 20 has been considered as a promising high-throughput microscale experimental method for detonation study because the conditions in the a School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China b Key Lab of Nanophotonics & Ultrafine Optoelectronic Systems, and School of laser-induced plasma are very similar to those in the chemical reaction zone behind the detonation wave of a detonating bulk explosive. 21 The past few years have witnessed the unprecedented rapid development of fast performance prediction and chemical reaction analysis by the interaction of nanosecond pulsed laser interaction with small dose energetic materials on the microgram to milligram scale.…”
Section: Introductionmentioning
confidence: 99%