High-Intensity Contact Opening Under 36-V DC Voltage Application for Mild Hybrid Vehicles

Abstract: This paper concerns the study of contact opening under dc voltage in the case of high-intensity current (a few hundred amperes). The application fields are mainly automotive and aeronautical systems. An experimental device has been designed in order to study the opening of contacts under various conditions. The influence of several parameters on contact opening is studied. These are the following: the opening velocity, the current intensity through the closed contact, the nature of the contact materials (Ag, A… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…For other electrode materials several authors [14] observed that for I CC smaller than 40 A the arc duration was an increasing function of I CC . Besides, the constancy of the extinction distance has already been observed at atmospheric pressure for supply voltages of the order of 40 V DC [16] and was attributed to the appearance of instabilities of electromagnetic origin which destabilize the arc. -At high current value, the error bars are large because of instabilities which induce less reproducible measurement than at low current.…”
Section: Observations and Commentsmentioning
confidence: 87%
See 2 more Smart Citations
“…For other electrode materials several authors [14] observed that for I CC smaller than 40 A the arc duration was an increasing function of I CC . Besides, the constancy of the extinction distance has already been observed at atmospheric pressure for supply voltages of the order of 40 V DC [16] and was attributed to the appearance of instabilities of electromagnetic origin which destabilize the arc. -At high current value, the error bars are large because of instabilities which induce less reproducible measurement than at low current.…”
Section: Observations and Commentsmentioning
confidence: 87%
“…For every current values considered in this work, electric arc is even more unstable as the pressure is high and the mean stability length is in the range [2][3][4][5][6][7][8][9][10][11][12][13][14][15][16] cm. The influence of arc current intensity is more pronounced for pressure values below 6 Â 10 4 Pa.…”
Section: Estimation Of the Stability Length Of The Arcmentioning
confidence: 99%