2013
DOI: 10.1002/jnm.1888
|View full text |Cite
|
Sign up to set email alerts
|

High‐performance doubly fed induction machine drive system using predictive direct torque control drive system fed by indirect matrix converters

Abstract: SUMMARY This paper presents a novel predictive direct torque control for doubly fed induction machine based on indirect matrix converter (IMC), which is characterized by its simple structure, minimal‐torque ripple, and constant switching frequency. Nowadays, the control strategies based on predictive methods have proved their efficiency to improve drive systems capabilities. So, in this paper, one of the best predictive methods that have recently been suggested for doubly fed induction machine drive systems is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 23 publications
0
1
0
Order By: Relevance
“…Behnia et al proposed a control strategy using quasi-proportional resonant controller to suppress the negative sequence current component and harmonic current component of grid-connected. This strategy not only effectively suppressed the negative sequence component of grid-connected current caused by unbalanced grid voltage, but also suppressed the low-order harmonic current component introduced by grid voltage or power generation system [3][4]. Zhu et al analyzed and calculated the harmonics of three-phase rectifier-single-phase inverter used in traction power supply system, discussed the process of space vector pulse width modulation rectifier and sine-wave pulse-width modulation inverter, respectively, and obtained the specific harmonic frequency.…”
Section: ⅱ Iterature Reviewmentioning
confidence: 99%
“…Behnia et al proposed a control strategy using quasi-proportional resonant controller to suppress the negative sequence current component and harmonic current component of grid-connected. This strategy not only effectively suppressed the negative sequence component of grid-connected current caused by unbalanced grid voltage, but also suppressed the low-order harmonic current component introduced by grid voltage or power generation system [3][4]. Zhu et al analyzed and calculated the harmonics of three-phase rectifier-single-phase inverter used in traction power supply system, discussed the process of space vector pulse width modulation rectifier and sine-wave pulse-width modulation inverter, respectively, and obtained the specific harmonic frequency.…”
Section: ⅱ Iterature Reviewmentioning
confidence: 99%