1996
DOI: 10.1016/0021-9673(95)00789-x
|View full text |Cite
|
Sign up to set email alerts
|

High-performance liquid chromatographic analysis of retinal and retinol isomers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
22
0

Year Published

2000
2000
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(23 citation statements)
references
References 22 publications
1
22
0
Order By: Relevance
“…The HPLC system consisted of a Shimadzu LC‐9 A pump, a Shimadzu SIL‐6B/9 A autoinjector, a Shimadzu SPD‐2 A UV‐detector at 325 nm, an integrator (Turbochrom, version 4.0, Perkin‐Elmer, Cupertino, CA, USA), a Hichrom Hypersil column (4.6 × 150 mm, 3 μm particle size) and a 90:10 hexane:isopropanol mobile phase. This procedure was validated for fish organ homogenates where standard additions showed identification, precision, linearity and trueness of the method in line with descriptions from Nöll (1996). Dry matter content of the diets and fish samples were measured gravimetrically after freeze‐drying.…”
Section: Analysessupporting
confidence: 62%
See 1 more Smart Citation
“…The HPLC system consisted of a Shimadzu LC‐9 A pump, a Shimadzu SIL‐6B/9 A autoinjector, a Shimadzu SPD‐2 A UV‐detector at 325 nm, an integrator (Turbochrom, version 4.0, Perkin‐Elmer, Cupertino, CA, USA), a Hichrom Hypersil column (4.6 × 150 mm, 3 μm particle size) and a 90:10 hexane:isopropanol mobile phase. This procedure was validated for fish organ homogenates where standard additions showed identification, precision, linearity and trueness of the method in line with descriptions from Nöll (1996). Dry matter content of the diets and fish samples were measured gravimetrically after freeze‐drying.…”
Section: Analysessupporting
confidence: 62%
“…Vitamins A 1 and A 2 were measured in all diets, and whole body and liver homogenates using an HPLC procedure modified from Nöll (1996). The HPLC system consisted of a Shimadzu LC‐9 A pump, a Shimadzu SIL‐6B/9 A autoinjector, a Shimadzu SPD‐2 A UV‐detector at 325 nm, an integrator (Turbochrom, version 4.0, Perkin‐Elmer, Cupertino, CA, USA), a Hichrom Hypersil column (4.6 × 150 mm, 3 μm particle size) and a 90:10 hexane:isopropanol mobile phase.…”
Section: Analysesmentioning
confidence: 99%
“…The fatty acid composition in the oil was analyzed by gas liquid chromatography (Trace GC 2000) according to previously described methods,17,22 with some modifications; the fatty acids were esterified in 20% boron fluoride (BF 3 ) in methanol, and sample parallels were analyzed. The level of fat soluble vitamins A23,24 and E25 was analyzed by high-performance liquid chromatography, and the lipid peroxidation was analyzed by thiobarbituric acid reactive substances26,27 (Table 1). The seal oil was added with a combination of natural and synthetic tocopherols, the latter being dl-α tocopheryl acetate.…”
Section: Methodsmentioning
confidence: 99%
“…• C prior to analysis of fatty acid composition and didehydro-all-trans retinol (A 2 ) in marine oils was analysed by a modified HPLC method [36,37]. Briefly, the sample is saponified, while the unsaponified sample material is extracted, and analysed by a HPLC column (HICHROM 4,6  150 mm, LC-SI, 3m, Teknolab A/S) using UV-detector (Thermo Separations products, UV1000, Instrument-Teknikk AS) with reference to an external standard curve.…”
Section: Experimental Oilsmentioning
confidence: 99%