1985
DOI: 10.1016/s0378-4347(00)84522-3
|View full text |Cite
|
Sign up to set email alerts
|

High-performance liquid chromatographic determination of certain salicylates and their major metabolites in plasma following topical administration of a liniment to healthy subjects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2000
2000
2009
2009

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…SA was extracted with 5 mL of a mixture containing cyclohexane:ethylacetate:isopropanol (50:50:1). The sample was dried under N 2 gas and dissolved in 0.5 mL of the mobile phase (69:27:4 mix of water:methanol:glacial acetic acid) (Dadgar et al, 1985). Samples were filtered through a 0.22-mm filter, and 20 to 100 mL were used for high performance liquid chromatography.…”
Section: Sa Quantitationmentioning
confidence: 99%
“…SA was extracted with 5 mL of a mixture containing cyclohexane:ethylacetate:isopropanol (50:50:1). The sample was dried under N 2 gas and dissolved in 0.5 mL of the mobile phase (69:27:4 mix of water:methanol:glacial acetic acid) (Dadgar et al, 1985). Samples were filtered through a 0.22-mm filter, and 20 to 100 mL were used for high performance liquid chromatography.…”
Section: Sa Quantitationmentioning
confidence: 99%
“…AcidRP-HPLC-MS/SIM RP-HPLC-FLD lower limit of detection (LOD) and the limit of quantitation (LOQ) for GA, SUA and SA by applying ESI-MS detection was in the same order of magnitude that obtained by fluorescence detection: LOD between 5 12. and 7.12 ng/ml, LOQ between 16.23 and 20.87 ng/ml for GA, SUA and SA.…”
mentioning
confidence: 60%
“…The Table 3 Concentration of gentisic (GA), salicyluric (SUA) and salicylic acid (SA) in a pure plasma sample obtained by mass spectrometric (MS) and fluorescence detection (FLD) applying calibration with aqueous standards or spiked plasma Table 3 shows their concentrations obtained as mean of six consecutive determinations, which also depend on the detection method (MS and FLD) used. Compared to earlier published analytical procedures for the analysis of GA, SUA and SA in biological fluids, this new method provides a 100 times increase in sensitivity instead of using LLE [11,12] and a 20 times increase instead of using earlier described SPE procedures [17]. The concentrations achieved with the calibration established upon the injection of spiked plasma samples and the two different detection methods does not differ much except for SA, which can be explained by the stronger tailing of this substance using FLD, caused by interference with coeluting plasma components.…”
Section: Quantitative Analysis Using Rp-lc-fld and Rp-lc-esi-sim/msmentioning
confidence: 98%
See 1 more Smart Citation
“…So scientists have reported many methods for determinination of salicylic ion in the literature, varying from fluorometry, 2 chromatography, [3][4][5] and spectrophotometry 6,7 to volammetric procedures. Most of the methods are tedious and time-consuming.…”
Section: Introductionmentioning
confidence: 99%