2002
DOI: 10.1016/s0165-0270(02)00228-5
|View full text |Cite
|
Sign up to set email alerts
|

High-performance liquid chromatography/tandem mass spectrometry assay for the rapid high sensitivity measurement of basal acetylcholine from microdialysates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
88
1

Year Published

2002
2002
2017
2017

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 72 publications
(94 citation statements)
references
References 19 publications
5
88
1
Order By: Relevance
“…The limit of detection of ACh achieved by using LC-MS 2 was comparable to the detection that can be achieved using LC-ECD methods. However, obvious advantages of LC-MS 2 assays for the detection of ACh can be summarized as follows: (i) there is no enzymatic reactions needed in order to separate choline from ACh; (ii) the assay provides a means of confirming the identity of the analyte using the specific mass transition together with its chromatographic retention time, and (iii) although neostigmine was used in the present study, we recently showed (Hows et al, 2002) that LC-MS/MS allows ACh to be measured in dialysates without the need to add neostigmine or physostigmine to the perfusate.…”
Section: Technical Notementioning
confidence: 96%
See 1 more Smart Citation
“…The limit of detection of ACh achieved by using LC-MS 2 was comparable to the detection that can be achieved using LC-ECD methods. However, obvious advantages of LC-MS 2 assays for the detection of ACh can be summarized as follows: (i) there is no enzymatic reactions needed in order to separate choline from ACh; (ii) the assay provides a means of confirming the identity of the analyte using the specific mass transition together with its chromatographic retention time, and (iii) although neostigmine was used in the present study, we recently showed (Hows et al, 2002) that LC-MS/MS allows ACh to be measured in dialysates without the need to add neostigmine or physostigmine to the perfusate.…”
Section: Technical Notementioning
confidence: 96%
“…While the three monoamines, NE, DA, and 5-HT, have been detected simultaneously using LC with electrochemical detection (Heidbreder et al, 2001b), ACh was quantified by using a newly developed analytical method based on LC-MS 2 detection (Hows et al, 2002). In comparison with the most commonly used LC methods coupled with electrochemical detection, the LC-MS assay method used in the present study is very specific, minimizing the need to separate ACh from other components present in dialysates.…”
Section: Technical Notementioning
confidence: 99%
“…The use of electrospray ionization (ESI)-MS is rapidly expanding into the study of enzyme kinetics [17][18][19][20][21][22][23]. Also, combinations of chromatographic and electrophoretic separation methods with ESI-MS, such as liquid chromatography (LC)/MS [24], LC/tandem mass spectroscopy (MS/MS) [25], gas chromatography (GC)/MS [26], frontal affinity chromatography (FAC)/MS [27], or capillary electrophoresis (CE)/MS [28] have been reported for the determination of acetylcholine or the screening of AChE inhibitors. These methods are quite specific but have longer cycle times.…”
mentioning
confidence: 99%
“…NIH-PA Author Manuscript NIH-PA Author Manuscript [7][8][9]. Despite the successful applications of microdialysis sampling, the main limitations for sampling large neuropeptides are a combination of their low relative recoveries and low basal concentrations.…”
Section: Nih-pa Author Manuscriptmentioning
confidence: 99%
“…It is by far the most commonly used method for the collection of low molecular weight hydrophilic neurotransmitters, such as acetylcholine, dopamine, and glutamate from mammalian brain with high relative recovery [7][8][9]. Despite the successful applications of microdialysis sampling, the main limitations for sampling large neuropeptides are a combination of their low relative recoveries and low basal concentrations.…”
Section: Introductionmentioning
confidence: 99%