The XIX International Conference on Electrical Machines - ICEM 2010 2010
DOI: 10.1109/icelmach.2010.5607865
|View full text |Cite
|
Sign up to set email alerts
|

High performance power converter for combined batteries-supercapacitor systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…The determination of the coefficients C hyst and C ec can be performed according to [21][22][23], and requires the knowledge of the data sheet of the magnetic laminations constituting the stator and the rotor of the motor. Experimental corrections [24][25][26][27] can be introduced to take into account the increase due to PWM inverter supply. From the second equation of the set of Eq.…”
Section: Iron Lossesmentioning
confidence: 99%
“…The determination of the coefficients C hyst and C ec can be performed according to [21][22][23], and requires the knowledge of the data sheet of the magnetic laminations constituting the stator and the rotor of the motor. Experimental corrections [24][25][26][27] can be introduced to take into account the increase due to PWM inverter supply. From the second equation of the set of Eq.…”
Section: Iron Lossesmentioning
confidence: 99%
“…The model and the operating modes of the power converter have been initial proposed and experimental validated [5]- [7] in the case of the traction drive with induction machine. Here the model and a brief description of the operating modes are reported, which are necessary to analyze the traction system performances.…”
Section: B Power Converter Model and Operating Modesmentioning
confidence: 99%
“…The last two operating modes 4 and 5 are the main procedures for performing the stabilization action of the supercapacitor charge. In the operating mode 4 (f 1 ≠0; f 2 ≠0), a small part of the PEMFC energy is transferred to supercapacitor bank during the zero sequence of inverter 1 and by means of suitable control algorithm, it is possible to keep, at the same time, the require voltage on the motor [5]- [7]. Moreover, when the amplitude of the reference space vector of the motor is constant for instance, the strength of the supercapacitor recharge can be changed by means the variation of the utilization of the zero sequence of the inverter 1.…”
Section: B Power Converter Model and Operating Modesmentioning
confidence: 99%
“…Some new applications require acquisition systems with precision in the order of few tens of parts per million, capable of digitizing and providing data to the controller within a very short delay, in the order of few µs. This is the case, for example, of smart power flow management between separate energy storage units [8] and high-performance electric vehicles [9].…”
Section: Introductionmentioning
confidence: 99%