Green Chromatographic Techniques 2013
DOI: 10.1007/978-94-007-7735-4_4
|View full text |Cite
|
Sign up to set email alerts
|

High Performance Thin-Layer Chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 66 publications
0
4
0
Order By: Relevance
“…28,38,39 Adopting the 3R green philosophy (reuse, replace, reduce), the sustainability extent of HPTLC could be greatly promoted through either substituting hazardous solvents with eco-friendlier ones or reducing their consumption. 19,20…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…28,38,39 Adopting the 3R green philosophy (reuse, replace, reduce), the sustainability extent of HPTLC could be greatly promoted through either substituting hazardous solvents with eco-friendlier ones or reducing their consumption. 19,20…”
Section: Resultsmentioning
confidence: 99%
“…28,38,39 Adopting the 3R green philosophy (reuse, replace, reduce), the sustainability extent of HPTLC could be greatly promoted through either substituting hazardous solvents with eco-friendlier ones or reducing their consumption. 19,20 Consequently, our efforts were focused on excluding any reported hazardous solvents used for ALF and SOL separation, like methanol, acetonitrile, chloroform, dichloromethane and toluene, and resorting to greener ones as per the Glax-oSmithKline (GSK) solvent sustainability guide. 40 Of these solvents, n-butanol, isopropanol, ethanol, ethyl acetate and acetone were examined in various ratios for efficient separation of the studied drug mixture.…”
Section: Development and Optimization Of Hptlc Separationmentioning
confidence: 99%
See 1 more Smart Citation
“…The most commonly used measure of lipophilicity is partition coefficient, log P, which represents the ratio of equilibrium concentrations of a substance in two phases of a system consisting of 1octanol and water [14,15]. In addition to the partition coefficient, chromatographic parameters, RM 0 , m, and C0, obtained by reversed-phase thin layer chromatography (RPTLC) [16][17][18][19] are used as reliable alternative measures of lipophilicity. The contemporary design of biologically active compounds, beside lipophilicity, requires a relevant assessment of the risks of their toxic effects in the environment and the study of the conditions under which they may be manifested.…”
Section: Introductionmentioning
confidence: 99%