2014
DOI: 10.1039/c3tc32052a
|View full text |Cite
|
Sign up to set email alerts
|

High-performance two-photon absorption luminophores: large action cross sections, free from fluorescence quenching and tunable emission of efficient non-doped organic light-emitting diodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
18
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 81 publications
1
18
0
Order By: Relevance
“…3, the PL intensity changed a lot. When f w increased to 50 %, nearly no fluorescence of Nph-An can be observed, which may be attributed to the dipole-dipole interaction between the fluorescent molecule in its excited state and the surrounding solvent molecules [23]. As f w is further increased and higher than 50 %, the emission intensity is enhanced.…”
Section: Resultsmentioning
confidence: 96%
“…3, the PL intensity changed a lot. When f w increased to 50 %, nearly no fluorescence of Nph-An can be observed, which may be attributed to the dipole-dipole interaction between the fluorescent molecule in its excited state and the surrounding solvent molecules [23]. As f w is further increased and higher than 50 %, the emission intensity is enhanced.…”
Section: Resultsmentioning
confidence: 96%
“…SPOTPE was synthesized according to the references [ 35 , 36 ] ( Scheme S1 ). Bromotriphenylethylene (4.00 g, 11.93 mmol), 4-hydroxyphenylboronic acid (1.97 g, 14.28 mmol), potassium carbonate aqueous solution (2 mol/L, 7.0 mL), tetrabutyl ammonium bromide (150 mg), and Pd(PPh 3 ) 4 (25 mg) were dissolved into 50 mL degassed tetrahydrofuran in a three-necked flask equipped with a magnetic stirrer under nitrogen atmosphere.…”
Section: Methodsmentioning
confidence: 99%
“…9 Although many reports have used TPE derivatives in the field of bioimaging and biosensing, 5 examples of TPE derivatives specifically optimized in view of application in 2PFM are surprisingly scarce. [10][11][12] Indeed, 2PFM presents significant advantages over classical confocal fluorescence: first, quadratic dependence of the 2PA phenomenon versus light intensity provides a strong control over the excitation volume (restricted to the focal point of the incident laser source), and thus an improved resolution and facilitated reconstruction of a 3D image; second, the use of NIR light source leads to improved penetration of light within the tissue and reduced autoluminescence. 13,14 2PFM relies on the two-photon absorption (2PA) 15 and thus requires the use of specifically engineered luminescent probes.…”
Section: Introductionmentioning
confidence: 99%