High-Power Radiofrequency Catheter Ablation of Atrial Fibrillation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
42
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 87 publications
(47 citation statements)
references
References 21 publications
2
42
0
Order By: Relevance
“…This was shown in a recently published multicenter study by Winkle et al where long procedure times and RF times were found despite the use of a heterogeneous HPSD strategy. Baher et al used 50 W for 5 seconds and found similar safety and efficacy with shorter procedure duration, compared with conventional PVI. Bourier et al found larger but shallower lesions with similar lesion volumes, using HPSD in an in vitro model.…”
Section: Discussionmentioning
confidence: 99%
“…This was shown in a recently published multicenter study by Winkle et al where long procedure times and RF times were found despite the use of a heterogeneous HPSD strategy. Baher et al used 50 W for 5 seconds and found similar safety and efficacy with shorter procedure duration, compared with conventional PVI. Bourier et al found larger but shallower lesions with similar lesion volumes, using HPSD in an in vitro model.…”
Section: Discussionmentioning
confidence: 99%
“…15 The incidence of the esophageal thermal injury assessed by late gadolinium enhancement magnetic resonance imaging in HP short-duration RF application (50 W for 5 seconds) was reported to be similar to that in LP long-duration RF application (≤35 W for 10 to 30 seconds). 12 The incidence of endoscopically detected esophageal lesion after AI-guided PV isolation with relatively HP RF application on the esophagus (35 W, target AI > 300) was reported to be low (erythema/erosion was 1.2% and no ulceration). 16 These results suggested that the relatively HP short-duration RF application could complete CPVI safely.…”
Section: Complicationsmentioning
confidence: 98%
“…[6][7][8] However, these studies did not evaluate the impact of RF application power on AI-guided CPVI. Several previous studies reported that HP RF application could reduce procedure time [9][10][11][12] but might increase complications related to RF application (steam pops, pericardial effusion and gastrointestinal complaints). 10 Theoretically, AI-guided HP RF application can create similar RF lesions for a short duration without excessive RF application.…”
mentioning
confidence: 99%
“…The complications rate was remarkably low, and this has encouraged many to start utilizing HPSD. Baher et al used gadolinium‐enhanced magnetic resonance imagings and endoscopy to evaluate 574 patients undergoing ablation at 50 W for 5 seconds and compared them with 113 patients undergoing ablation at less than 35 W for 10 to 30 seconds. Like the earlier studies, with HPSD they found a marked reduction in procedure time from 251 ± 101 to 149 ± 65 ( P < .001) and RF ablation time from 55.0 ± 19.2 to 37.9 ± 13.9 ( P < .001).…”
mentioning
confidence: 99%