2019
DOI: 10.1016/j.nuclphysa.2019.04.002
|View full text |Cite
|
Sign up to set email alerts
|

High precision half-life measurement of 125Cs and 125Xe with γ-spectroscopy

Abstract: In order to provide data for the simulation of the astrophysical γ-process, the cross section measurement of the 124 Xe(p,γ) 125 Cs reaction is in progress at MTA Atomki using the activation technique. Precise information on the decay characteristics of the reaction products is of crucial importance for measurements carried out using this method. The half-lives of the produced 125 Cs and its daughter 125 Xe are published in previous works, but with large uncertainties and ambiguous values. To make these nuclea… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…we assume that weak γ-rays, emitted after the β-decay of other isotopes, with energies within the resolution of the HPGe detector contribute to yield of the peak of our interest (see e.g. [19]). However, the derived half-life values, based on the countings of different γ-transitions are statistically consistent and this indicates that the measured γ-yields contain no parasitic con- 3 Relative uncertainties are given in parenthesis.…”
Section: Data Analysis and Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…we assume that weak γ-rays, emitted after the β-decay of other isotopes, with energies within the resolution of the HPGe detector contribute to yield of the peak of our interest (see e.g. [19]). However, the derived half-life values, based on the countings of different γ-transitions are statistically consistent and this indicates that the measured γ-yields contain no parasitic con- 3 Relative uncertainties are given in parenthesis.…”
Section: Data Analysis and Resultsmentioning
confidence: 99%
“…After the irradiation, the samples were placed at 21 cm distance from the endcap of the detector. The nuclear electronics used for the present half-life measurement was similar to the one used in the past for the precise half-life measurements carried out at Atomki [16][17][18][19]. Namely, the signals from the detector preamplifier were first shaped (the shaping time was set to 3μs) and amplified by an ORTEC model 671 module.…”
Section: Methodsmentioning
confidence: 99%