2020
DOI: 10.1109/access.2020.2979757
|View full text |Cite
|
Sign up to set email alerts
|

High Precision Tri-Axial Quartz Flexible Accelerometers Resolution Measurement Method Based on Tri-Axial Turntable

Abstract: Aiming at the high requirements of the experimental equipment for the measurement of high precision quartz flexible accelerometer resolution, the gravity measured by high precision tri-axial accelerometers was subdivided by the tri-axial turntable. Tri-axial quartz flexible accelerometers resolution measurement model was established and general mathematical expression for the resolution measurement was derived. Based on the mathematical expression, the effective angle range that satisfied the measurement condi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…However, the fault diagnosis of QFA mounted on carriers is difficult to proceed especially on the fracture state caused by an enormous external impact. Most studies tend to propose the method aiming at the calibration of the QFA without considering the detachability from applications [16][17][18][19]. They are meaningful in the situation that the QFA is rarely used; nevertheless, for the applications where QFA cannot be disassembled and replaced expediently under a damage case, rebuilding the effective closeloop system is more valuable.…”
Section: Introductionmentioning
confidence: 99%
“…However, the fault diagnosis of QFA mounted on carriers is difficult to proceed especially on the fracture state caused by an enormous external impact. Most studies tend to propose the method aiming at the calibration of the QFA without considering the detachability from applications [16][17][18][19]. They are meaningful in the situation that the QFA is rarely used; nevertheless, for the applications where QFA cannot be disassembled and replaced expediently under a damage case, rebuilding the effective closeloop system is more valuable.…”
Section: Introductionmentioning
confidence: 99%
“…restricting the further improvement of navigation performance of inertial navigation system [1]. In recent years, the research on the influence of temperature [2][3][4][5], magnetic circuit [6][7][8], pendulum reed structure [9][10][11], calibration error [12][13][14][15][16] and other factors on the performance of QFA has been relatively mature, but the research on the internal components of QFA and readout circuit generated noise during operation is relatively few. Zhou et al [17] designed a single carrier modulated differential capacitance detection circuit, which can effectively eliminate the influence of parasitic resistance and capacitance and theoretically ensure the stability of sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the advantages of high positioning accuracy, short observation time and easy operation, it is widely used in engineering surveys. During centering rod surveying, roll and pitch are usually measured by accelerometers [6][7][8], whereas yaw is generally measured by a magnetometer [9,10]. As a consequence, the accuracy of pitch measurement is affected by the errors of the accelerometer itself [11].…”
Section: Introductionmentioning
confidence: 99%