2014
DOI: 10.1007/s00167-014-2920-x
|View full text |Cite
|
Sign up to set email alerts
|

High reliability in digital planning of medial opening wedge high tibial osteotomy, using Miniaci’s method

Abstract: Diagnostic study, Level II.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
87
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 96 publications
(88 citation statements)
references
References 36 publications
1
87
0
Order By: Relevance
“…All osteotomies were performed by one senior orthopedist (Y.R.Z.). Preoperative planning (correction angle and amount of opening gap) was determined as previous described by using the Fujisawa point and Miniaci method [21][22][23] .…”
Section: Surgical Proceduresmentioning
confidence: 99%
“…All osteotomies were performed by one senior orthopedist (Y.R.Z.). Preoperative planning (correction angle and amount of opening gap) was determined as previous described by using the Fujisawa point and Miniaci method [21][22][23] .…”
Section: Surgical Proceduresmentioning
confidence: 99%
“…Preoperative planning was performed according to the "Miniaci's method" and proper gap diameter was measured with the patient standing in the whole lower extremity anteroposterior view. 8,9 After spinal anesthesia, the tourniquet was inflated to 350 mm Hg and a routine arthroscopic examination was done using anteromedial and anterolateral portals. If necessary, arthroscopic procedures, such as meniscectomy, meniscal repair, debridement, and/or microfracture chondroplasty, were done.…”
Section: Surgical Procedures and Topical Tranexamic Acid Administrationmentioning
confidence: 99%
“…Pre-operative planning is mandatory in osteotomy surgery (Elson et al, 2014) and this was performed to generate a simulated correction angle (Dugdale et al, 1992) and opening distance (Hernigou, 2002). Medial opening wedge HTO was performed (Lobenhoffer and Agneskirchner, 2003) to generate the planned opening distance before fixation with the TomoFix plate device (Depuy Synthes, Solothurn, Switzerland).…”
Section: Surgerymentioning
confidence: 99%
“…Medial opening wedge HTO was performed (Lobenhoffer and Agneskirchner, 2003) to generate the planned opening distance before fixation with the TomoFix plate device (Depuy Synthes, Solothurn, Switzerland). Achieved correction was judged from post-operative long leg alignment radiographs by measuring the mechanical tibiofemoral angle (Paley et al, 1994) and the transection point of the weight bearing axis through the tibial plateau, expressed as a percentage of the tibial width from medial to lateral (Elson et al, 2014). Patients completed the Oxford knee score (Dawson et al, 1998).…”
Section: Surgerymentioning
confidence: 99%