2012
DOI: 10.1148/radiol.12112033
|View full text |Cite
|
Sign up to set email alerts
|

High-Resolution 3D MR Microangiography of the Rat Ocular Circulation

Abstract: Purpose:To develop high-spatial-resolution magnetic resonance (MR) microangiography techniques to image the rat ocular circulation. Materials and Methods:Animal experiments were performed with institutional Animal Care Committee approval. MR microangiography (resolution, 84 3 84 3 84 µm or 42 3 42 3 84 µm) of the rat eye (eight rats) was performed by using a custom-made small circular surface coil with an 11.7-T MR unit before and after monocrystalline iron oxide nanoparticle (MION) injection. MR microangiogra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
8
1

Relationship

7
2

Authors

Journals

citations
Cited by 20 publications
(18 citation statements)
references
References 18 publications
0
18
0
Order By: Relevance
“…In addition to BF MRI, anatomical MRI has also been applied to study the retina using a variety of contrasts, such as T1 [45,46], T2 [45-47], balanced steady state free precession [48], diffusion [45,47], and manganese-enhanced [49-51], chromium-enhanced [52], microangiographic [53] MRI. Functional MRI based on BOLD [54,55,46], blood-volume [56,57], manganese-enhanced [58,50], balanced steady-state free precession [48], and diffusion [59] contrasts have also been demonstrated.…”
Section: Discussionmentioning
confidence: 99%
“…In addition to BF MRI, anatomical MRI has also been applied to study the retina using a variety of contrasts, such as T1 [45,46], T2 [45-47], balanced steady state free precession [48], diffusion [45,47], and manganese-enhanced [49-51], chromium-enhanced [52], microangiographic [53] MRI. Functional MRI based on BOLD [54,55,46], blood-volume [56,57], manganese-enhanced [58,50], balanced steady-state free precession [48], and diffusion [59] contrasts have also been demonstrated.…”
Section: Discussionmentioning
confidence: 99%
“…The animal preparation was similar to that reported previously. 14,15 Adult male Sprague–Dawley rats ( n = 26, 250–300g) were anesthetized with 2% isoflurane, intubated and ventilated (Harvard apparatus, Model 683, South Natick, MA). The respiratory rate of the ventilator was set between 57 and 60 stroke/min.…”
Section: Methodsmentioning
confidence: 99%
“…Heart rate and blood oxygen saturation level were continuously monitored by a MouseOx system (STARR Life Science Corp., Oakmont, PA) and maintained within normal ranges. An established CBV fMRI technique was employed (Mandeville et al, 1998) by using 30 mg/kg monocrystalline iron oxide nanoparticles (MION) at 11.7 T to minimize the BOLD contribution (Shih et al, 2011, 2012c). …”
Section: Methodsmentioning
confidence: 99%