High Resolution and High Contrast Bio-Medical X-ray Imaging Technique Using Synchrotron Radiation in PLS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…To provide insight into simulated betatron phase-contrast images, especially in the context of sub-micron resolution, we will consider a water droplet example containing two embedded virus particles. The water droplet is approximated as a uniform-density sphere of radius 20 µm, centered at (x = 0, y = 0), with a tabulated X-ray index of refraction 20 The two virus particles will be approximated as a uniform sphere of radius 200 nm, one centered at (x = 0, y = 0) and the other at various separation distances, with the index of refraction being different from water by ∆δ virus and ∆β virus . For example, a water droplet with a virus particle that is optically identical to water would be accounted for as a uniform droplet of index (δ water , β water ) and a relative virus contribution of ∆δ virus = ∆β virus = 0.…”
Section: Simulationsmentioning
confidence: 99%
“…To provide insight into simulated betatron phase-contrast images, especially in the context of sub-micron resolution, we will consider a water droplet example containing two embedded virus particles. The water droplet is approximated as a uniform-density sphere of radius 20 µm, centered at (x = 0, y = 0), with a tabulated X-ray index of refraction 20 The two virus particles will be approximated as a uniform sphere of radius 200 nm, one centered at (x = 0, y = 0) and the other at various separation distances, with the index of refraction being different from water by ∆δ virus and ∆β virus . For example, a water droplet with a virus particle that is optically identical to water would be accounted for as a uniform droplet of index (δ water , β water ) and a relative virus contribution of ∆δ virus = ∆β virus = 0.…”
Section: Simulationsmentioning
confidence: 99%
“…This imaging mode can be applied to observe e.g. scattering signals from ultra-structures [31]. It is obvious that the distinct difference of Eq.…”
Section: Derivation Of Contrast Transfer Under Zernike Phase Contrastmentioning
confidence: 99%
“…The installation of white beam mode at any synchrotron beamline depends on its optical design, spectral distribution of the incident beam, heat load etc., and varies in the way by which these challenges are addressed for instrumental and personal safety. Some of the bending magnet beamlines with white beam mode of operation implemented are the Advanced Photon Source (APS), USA [2BM] (Wang et al, 2001), Pohang Light Source, South Korea [5C1] (Jung et al, 2002;Huang et al, 2010), Canadian Light Source, Canada [05B1-1] (Wysokinski et al, 2007), ANKA, Germany [TOPO-TOMO] (Rack et al, 2009), APS, USA [7-BM] (Rivers, 2016), Diamond Light Source, UK [B16] (Zhou et al, 2018), Elettra, Italy [SYRMEP] (Sena et al, 2015) etc. These beamlines offer a flux density of $10 12 photons s À1 mm À2 .…”
Section: Introductionmentioning
confidence: 99%