2007
DOI: 10.1111/j.1365-2818.2007.01765.x
|View full text |Cite
|
Sign up to set email alerts
|

High‐resolution compact X‐ray microscopy

Abstract: SummaryWe demonstrate compact full-field soft X-ray transmission microscopy with sub 60-nm resolution operating at λ = 2.48 nm. The microscope is based on a 100-Hz regenerative liquid-nitrogen-jet laser-plasma source in combination with a condenser zone plate and a micro-zone plate objective for highresolution imaging onto a 2048 × 2048 pixel CCD detector. The sample holder is mounted in a helium atmosphere and allows imaging of both dry and wet specimens. The microscope design enables fast sample switching an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
84
0
2

Year Published

2009
2009
2020
2020

Publication Types

Select...
5
3
2

Relationship

0
10

Authors

Journals

citations
Cited by 154 publications
(86 citation statements)
references
References 30 publications
0
84
0
2
Order By: Relevance
“…Ethanol droplet-based SXR source at k = 3.37 nm, combined with a zone plate objective allowed to capture images with spatial resolution of 60 nm [12], later improved to *50 nm [13]. Liquid nitrogen-based SXR source at k = 2.48 nm was used to demonstrate recently a compact full-field soft X-ray transmission microscopy with sub-60 nm resolution, operating at 100 Hz repetition rate, with exposure times of less than 5 min using both dry and wet samples [14]. Tomographic high resolution imaging was also performed in the ''water-window'' spectral range with a diatom, acquiring a tilt series of 53 images covering 1808 with halfperiod spatial resolution of the tomogram approaching 140 nm [15].…”
Section: Introductionmentioning
confidence: 99%
“…Ethanol droplet-based SXR source at k = 3.37 nm, combined with a zone plate objective allowed to capture images with spatial resolution of 60 nm [12], later improved to *50 nm [13]. Liquid nitrogen-based SXR source at k = 2.48 nm was used to demonstrate recently a compact full-field soft X-ray transmission microscopy with sub-60 nm resolution, operating at 100 Hz repetition rate, with exposure times of less than 5 min using both dry and wet samples [14]. Tomographic high resolution imaging was also performed in the ''water-window'' spectral range with a diatom, acquiring a tilt series of 53 images covering 1808 with halfperiod spatial resolution of the tomogram approaching 140 nm [15].…”
Section: Introductionmentioning
confidence: 99%
“…Full-field transmission X-ray microscopy (TXM) using both synchrotron and tabletop X-ray sources has been accomplished at many facilities all over the world (Schneider, 1998;Chao et al, 2005;Yin et al, 2006;Sakdinawat & Liu, 2007;Takman et al, 2007;Chu et al, 2008;de Jonge et al, 2008;Kim et al, 2008;Chen et al, 2008;Andrews et al, 2010;Rehbein et al, 2009). The unique capability of imaging three-dimensional structure with spatial resolution down to a few tens of nanometers (Chao et al, 2005;Schneider et al, 2010; over a field of view of several tens of micrometers has made TXM a well recognized tool for research ranging from materials science (Chen et al, 2008;Li et al, 2009;Nelson et al, 2011) to biological studies (Larabell & Le Gros, 2004;Andrews et al, 2010;Patty et al, 2009;Schneider et al, 2010).…”
Section: Introductionmentioning
confidence: 99%
“…To enable soft x-ray microscopy for everyday use without waiting times due to limited beam time at large-scale facilities, lab-scale sources based on gas discharge or laser-produced plasmas for soft x-ray microscopy have been employed and considerable progress has been achieved in recent years [11][12][13][14][15]. For instance, making use of a master oscillator power amplifier (MOPA) laser with high average powers of up to 130 W at sub-ns pulse durations, Legall et al [15] have described a laser-induced plasma source generated in a liquid nitrogen cryo jet.…”
Section: Introductionmentioning
confidence: 99%